Evidence map›Paper›PMID 42076424›Full record

ArticleSensors (Basel, Switzerland)2026

High-Fidelity Weak Signal Extraction for Coiled Tubing Acoustic Telemetry via Micro-Lever Suspension and Joint Denoising.

Yingjian Xie, Hao Geng, Zhihao Wang, Haojie Xu, Hu Han, Dong Yang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yingjian XieHubei Key Laboratory of Oil and Gas Drilling and Production Engineering, Yangtze University, Wuhan 430100, China.
Hao GengHubei Key Laboratory of Oil and Gas Drilling and Production Engineering, Yangtze University, Wuhan 430100, China.
Zhihao WangHubei Key Laboratory of Oil and Gas Drilling and Production Engineering, Yangtze University, Wuhan 430100, China.
Haojie XuHubei Key Laboratory of Oil and Gas Drilling and Production Engineering, Yangtze University, Wuhan 430100, China.
Hu HanHubei Key Laboratory of Oil and Gas Drilling and Production Engineering, Yangtze University, Wuhan 430100, China.
Dong YangHubei Key Laboratory of Oil and Gas Drilling and Production Engineering, Yangtze University, Wuhan 430100, China.

Funding

the Intelligent Optical Fiber Logging and Digital Oil & Gas Field Technology Research Team Project of China T2023005the Key Equipment for Ultra-Deep Well Logging of China 2025ZD1402103the Open Fund of Hubei Key Laboratory of Oil and Gas Drilling and Production Engineering (Yangtze University) of China YQZC202512the Unconventional Intelligent Drilling and 10,000-meter Coiled Tubing Downhole Tools of China 2025ZD1404600
6 · The paper itself

Abstract

In Coiled Tubing (CT) acoustic telemetry, the reliability of surface signal reception is severely challenged by the "contact dead zone" of traditional probes and complex nonstationary environmental noise. To address these issues, this paper proposes a hardware-software integrated solution for high-fidelity signal extraction. In terms of hardware, a novel pickup probe based on the micro-lever principle is developed. By utilizing a pivoted lever structure with an optimized arm ratio of 2.6 to 1 and a full pressure-balanced mechanism, the design physically overcomes the contact dead zone inherent in traditional pressure-compensating probes and effectively isolates low frequency common-mode interference through a lateral floating architecture. In terms of software, a joint denoising model combining Complete Ensemble Empirical Mode Decomposition with Adaptive Noise and wavelet thresholding is proposed. A cross-correlation coefficient criterion is introduced to adaptively screen intrinsic mode functions and eliminate residual fluid turbulence noise. Field experiments on a 1500 ft full-scale circulation loop demonstrate that the proposed probe improves the detection sensitivity of the radial breathing mode by approximately 20.6 dB compared to the baseline, while effectively eliminating stick-slip friction noise during dynamic tripping. Furthermore, the joint algorithm increases the Signal to noise Ratio by an additional 16.9 dB under typical pumping conditions of 0.5 bpm, with a normalized cross-correlation exceeding 0.96. These results verify that the proposed method effectively solves the bottleneck of weak signal detection in deep wells, providing robust technical support for CT telemetry operations.

Indexed as

acoustic telemetryCEEMDANcoiled tubingjoint denoisingmicro-levernonlinear dead zone

Identifiers

PMID42076424
PMCPMC13120086

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.