ArticleSensors (Basel, Switzerland)2026
High-Fidelity Weak Signal Extraction for Coiled Tubing Acoustic Telemetry via Micro-Lever Suspension and Joint Denoising.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
In Coiled Tubing (CT) acoustic telemetry, the reliability of surface signal reception is severely challenged by the "contact dead zone" of traditional probes and complex nonstationary environmental noise. To address these issues, this paper proposes a hardware-software integrated solution for high-fidelity signal extraction. In terms of hardware, a novel pickup probe based on the micro-lever principle is developed. By utilizing a pivoted lever structure with an optimized arm ratio of 2.6 to 1 and a full pressure-balanced mechanism, the design physically overcomes the contact dead zone inherent in traditional pressure-compensating probes and effectively isolates low frequency common-mode interference through a lateral floating architecture. In terms of software, a joint denoising model combining Complete Ensemble Empirical Mode Decomposition with Adaptive Noise and wavelet thresholding is proposed. A cross-correlation coefficient criterion is introduced to adaptively screen intrinsic mode functions and eliminate residual fluid turbulence noise. Field experiments on a 1500 ft full-scale circulation loop demonstrate that the proposed probe improves the detection sensitivity of the radial breathing mode by approximately 20.6 dB compared to the baseline, while effectively eliminating stick-slip friction noise during dynamic tripping. Furthermore, the joint algorithm increases the Signal to noise Ratio by an additional 16.9 dB under typical pumping conditions of 0.5 bpm, with a normalized cross-correlation exceeding 0.96. These results verify that the proposed method effectively solves the bottleneck of weak signal detection in deep wells, providing robust technical support for CT telemetry operations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.