ArticleMicromachines2026
A Drive-Vibration Integrated Piezoelectric Actuator for Flexible Electrode Implantation.
Article in Micromachines, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A Review on the Research Progress of Imprint Film Materials for Nanoimprint Lithography.Micromachines · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
In this paper, a drive-vibration integrated piezoelectric actuator (DVIPA) is proposed for vibration-assisted implantation of flexible electrodes. Conventional implantation systems typically rely on separate actuation and vibration modules, which increase system complexity and limit integration. To address this limitation, the proposed DVIPA integrates driving and vibration functions within a single compact structure by employing two piezoelectric bimorphs for clamping and a piezoelectric stack for combined actuation. A composite excitation waveform, consisting of high-frequency sinusoidal signals superimposed on the rising stage of a low-frequency trapezoidal wave, is applied to simultaneously generate forward motion and vibration. This configuration enables a coupled motion mode that facilitates insertion while reducing the risk of buckling. A prototype of the DVIPA was developed and experimentally evaluated. The results show that vibration-assisted implantation can be achieved under various operating conditions, with independently adjustable driving and vibration parameters. A maximum speed of 328 μm/s is obtained, meeting the requirements for flexible electrode implantation. Agarose gel experiments further demonstrate that vibration frequencies above 40 Hz and voltages between 20 and 40 V can effectively assist implantation of polydimethylsiloxane (PDMS) without buckling failure. Overall, the proposed actuator provides a compact and integrated solution for vibration-assisted implantation, offering potential advantages in applications with limited space.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.