ArticleBioengineering (Basel, Switzerland)2026
Viscoelastic Properties of Porcine Pericardium Under Biaxial Tensile Creep and Stress Relaxation: Application for Novel Aortic Valve Bioprosthesis Design.
Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To design novel heart valve bioprostheses, it is extremely important to predict leaflet failure and fatigue for 10-20 years, as the aortic valve opens and closes approximately 40 million times per year. Most studies devoted to aortic valve leaflets mechanical tests employ uniaxial or biaxial tests, which do not fully and explicitly describe the time-dependent biomechanical behavior of this tissue. The aim of this study was to evaluate the viscoelastic response of porcine pericardium using biaxial tensile tests. Biaxial creep tests were performed on a biaxial test machine to evaluate the circumferential and axial behavior of the porcine pericardium under creep testing, and biaxial stress relaxation was used to complement creep. The results showed that the creep behavior was the same in both directions after 1 s, 60 s, 300 s, 900 s, and 1800 s. After 30 min of creep, deformation in the circumferential and radial directions was 3303 × 10-6 and 5192.9 × 10-6, respectively. Stress relaxation tests showed the same behavior as creep. At stress relaxation test after 30 min, the pericardium deformation in the circumferential and radial directions was 15.28 kPa and 9.6 kPa, respectively. The Prony series with Levenberg-Marquardt as the optimizer was used to obtain material parameters to use for finite element analysis. The data obtained during such tests can be employed in numerical FSI simulations of novel aortic valve bioprosthesis long-term performance in a patient's body.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.