Evidence map›Paper›PMID 42072183›Full record

ArticleBioengineering (Basel, Switzerland)2026

Patient-Specific Finite Element Analysis of Tibialis Anterior Tendon Insertion Variability and Its Impact on First Ray Biomechanics.

Recep Taşkin, İrfan Kaymaz, Osman Yazici, Fatih Ugur

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Recep TaşkinDepartment of Orthopedics and Traumatology, Faculty of Medicine, Kastamonu University, 37150 Kastamonu, Turkey.
İrfan KaymazDepartment of Mechanical Engineering, Faculty of Engineering and Architecture, Erzurum Technical University, 25050 Erzurum, Turkey.ORCID 0000-0002-9391-7218
Osman YaziciDepartment of Mechanical Engineering, Faculty of Engineering and Architecture, Erzurum Technical University, 25050 Erzurum, Turkey.ORCID 0009-0001-0212-4299
Fatih UgurDepartment of Orthopedics and Traumatology, Faculty of Medicine, Kastamonu University, 37150 Kastamonu, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHallux valgus (HV) is a complex forefoot deformity influenced by interactions between osseous alignment, ligamentous restraint, and muscle-tendon forces. While the biomechanical role of ligament laxity and bone geometry has been extensively investigated, the contribution of tibialis anterior (TA) tendon insertion variability to medial column mechanics remains insufficiently understood. MATERIALS AND

methodsA patient-specific finite element model of the foot was developed from high-resolution computed tomography data. Five anatomically documented TA distal insertion configurations were modeled, representing different distributions of attachment to the medial cuneiform and first metatarsal base. All simulations were performed under identical boundary and loading conditions representative of the stance phase of gait. Global (full-foot) and local (first bone and first metatarsal) mechanical responses were quantified using total deformation, equivalent von Mises stress, and strain distributions.

resultsMarked differences in mechanical behavior were observed across TA insertion types. The metatarsal-dominant configuration (Type 3) demonstrated the highest global and local deformation values (global deformation: 1.0928 mm; first bone deformation: 1.0928 mm) and elevated strain distributions, whereas the medial-dominant configuration (Type 2) showed minimal deformation (global: 0.0727 mm; first bone: 0.0350 mm) but the highest global equivalent von Mises stress (5.7698 MPa). The single-band insertion to the medial cuneiform (Type 5) produced the greatest localized stress in the first bone region (3.8634 MPa). Representative strain maps revealed distinct spatial redistribution patterns within the medial column associated with TA insertion geometry.

conclusionsThis patient-specific finite element analysis indicated that distal TA insertion variability alone can substantially modify deformation, stress, and strain patterns within the medial column. These findings suggested that TA insertion anatomy may act as a biomechanical modulator of first-ray mechanics and should be considered in future studies investigating hallux valgus pathomechanics and personalized treatment strategies.

Indexed as

finite element analysisfirst ray biomechanicshallux valgusmedial columntendon insertiontibialis anterior

Identifiers

PMID42072183
PMCPMC13114066

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.