Evidence map›Paper›PMID 42069974›Full record

ArticleArchives of orthopaedic and trauma surgery2026

Assessing PHILOS plate as an alternative fixation method for pediatric femoral neck fractures: a biomechanical comparison with cannulated screws.

Bo Shiun Lim, Yu-Po Wang, Shang-Ta Chung, Chi-Hsiu Wang, Shu-Wei Chang, Ting-Ming Wang, Chih-Kai Hong

Abstract readComparative Study
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Bo Shiun LimDepartment of Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan.
Yu-Po WangDepartment of Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan.
Shang-Ta ChungDepartment of Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan.
Chi-Hsiu WangDepartment of Nursing, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan City, Taiwan.
Shu-Wei ChangDepartment of Civil Engineering, National Taiwan University, Taipei, Taiwan.
Ting-Ming WangDepartment of Orthopaedic Surgery, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan.
Chih-Kai HongDepartment of Orthopaedic Surgery, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan. yayahong@gmail.com.

Funding

National Cheng Kung University Hospital NCKUH-11507007National Science and Technology Council 112-2314-B-006-115-MY3National Taiwan University Hospital 115-O0002National Taiwan University Hospital 115-S0245
6 · The paper itself

Abstract

backgroundPediatric femoral neck fractures require stable fixation to avoid complications. It remains unclear whether fixation with the Proximal Humeral Internal Locking System (PHILOS) can serve as an alternative to cannulated screw fixation. The purpose of this study was to compare the biomechanical properties of PHILOS and cannulated screws for stabilizing unstable pediatric femoral neck fractures using a synthetic bone model. MATERIALS AND

methodsTwelve fourth-generation synthetic composite femurs were randomly assigned to screw fixation (Group S) or PHILOS fixation (Group P) (n = 6 each). A standardized vertically oriented Delbet type II osteotomy was created in all specimens. Group S was fixed with three 6.5-mm cannulated screws, whereas Group P received a PHILOS plate with 3.5-mm locking screws. Each specimen underwent a standardized loading protocol using a universal testing machine. Axial stiffness, cyclic displacement, ultimate failure load, and failure modes were recorded and statistically compared between groups.

resultsNo statistically significant difference was found in axial stiffness between Group P (746 ± 300 N/mm) and Group S (753 ± 256 N/mm) (p = 1.000). Displacement after cyclic loading was significantly greater in Group P (1.42 ± 0.3 mm) compared with Group S (0.57 ± 0.2 mm) (p = 0.004). The ultimate failure load was higher in Group S (2378 ± 513 N) than it was in Group P (1652 ± 206 N) (p = 0.025). Upon reaching ultimate load, all specimens in both groups failed at the femoral head region due to femoral head broken.

conclusionsThe adult PHILOS plate with 3.5-mm locking screws demonstrated inferior biomechanical stability compared with three 6.5-mm cannulated screws in this synthetic composite femur model. LEVEL OF EVIDENCE: Controlled laboratory study.

Indexed as

Bone PlatesBone ScrewsFemoral Neck FracturesFracture Fixation, InternalBiomechanical PhenomenaChildHumansBiomechanicsPediatric femoral neck fractureProximal humeral internal locking systemScrew fixation

Identifiers

PMID42069974
PMCPMC13135569

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.