ArticleNeuroradiology2026
First clinical experience with the surpass elite flow diverter in the treatment of intracranial aneurysms.
Article in Neuroradiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe Surpass Elite (Stryker Neurovascular) is a third-generation flow diverter featuring modified braid architecture with increased braid angle and novel surface charge neutralization treatment. This study presents the first clinical experience with the Surpass Elite globally.
methodsA retrospective analysis of 81 consecutive cases (78 unique patients) treated with the Surpass Elite across four centers by two operators from January to July 2025 was performed. Data collected included patient demographics, aneurysm characteristics, procedural details, technical success, complications, and angiographic/clinical outcomes. Primary endpoints were technical success rate, perioperative safety profile, and aneurysm occlusion rates at approximately 6-month follow-up.
resultsThe cohort comprised 78 unique patients (76.9% female, mean age 59.2 ± 14.5 years) with 81 aneurysms treated using 112 total devices (mean 1.38 devices per case). Aneurysms were predominantly located in the internal carotid artery (75.3%). Technical success was achieved in 100% of cases regardless of access site. Balloon angioplasty was required in only 13.6% of cases. Among 61 aneurysms with complete angiographic follow-up at a mean of 6 months, complete occlusion (RROC Class I or OKM Grade D) was achieved in 78.7%. In-stent stenosis (< 50%) was observed in only 3.3% of cases with follow-up imaging, suggesting favorable vessel remodeling with minimal intimal hyperplasia. The immediate intraprocedural complication rate was 2.5% (2/81), including one device-related microperforation (complete recovery) and one intraoperative thrombosis (managed successfully intraprocedurally; delayed stroke from subsequent medication noncompliance). Delayed complications within 30 days included one stroke from antiplatelet noncompliance (fatal) and one access-site hematoma (recovered). One delayed adverse event beyond 30 days (delayed right temporal intraparenchymal hemorrhage at 10 months) was observed in a patient on dual antiplatelet therapy plus apixaban and was attributed to cerebral amyloid angiopathy; this event was not considered device- or procedure-related. Overall mortality was 7.4% (6/81): one death (1.2%) was procedure-related (stroke from medication noncompliance), one death occurred within 30 days from post-SAH vasospasm in a ruptured aneurysm case, and four deaths occurred after 30 days (recurrent ICH at 3 weeks, acute respiratory failure with acute on chronic heart failure at 5 months, homicide at approximately 6 months, and one of unknown cause), none of which were device- or procedure-related.
conclusionThis first published clinical experience with Surpass Elite flow diverter demonstrates reliable technical deliverability, favorable early occlusion rates comparable to established flow diverters, and a satisfactory safety profile. The low rates of required balloon angioplasty support the clinical benefit of the modified braid architecture. These preliminary findings support the continued clinical evaluation of the Surpass Elite in larger prospective cohorts.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.