Evidence map›Paper›PMID 42065782›Full record

ArticleAnalytical and bioanalytical chemistry2026

High-efficiency generation of stably transduced monoclonal cell lines via a laser-induced jetting microfluidic platform.

Fuyuan Chen, Baojian Zhang, Yuntong Wang, Hao Peng, Yu Wang, Zhixiong Song, Meina Chen, Xuan Yang, Peng Liang, Yue Qu and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Fuyuan Chen *State Key Laboratory of Advanced Manufacturing for Optical Systems, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China.
Baojian Zhang *School of Ophthalmology & Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Yuntong WangState Key Laboratory of Advanced Manufacturing for Optical Systems, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China.
Hao PengState Key Laboratory of Advanced Manufacturing for Optical Systems, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China.
Yu WangState Key Laboratory of Advanced Manufacturing for Optical Systems, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China.
Zhixiong SongAnhui University of Chinese Medicine, Hefei, 230012, Anhui, China.
Meina ChenSchool of Ophthalmology & Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Xuan YangCollege of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, Zhejiang, China.
Peng LiangState Key Laboratory of Advanced Manufacturing for Optical Systems, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China. liangpeng1@ciomp.ac.cn.
Yue QuHaining High-Tech Research Institute, Jiaxing, 314408, Zhejiang, China. yue.qu@hn-hti.org.
Bei LiState Key Laboratory of Advanced Manufacturing for Optical Systems, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China. beili@ciomp.ac.cn.

Funding

ilin Province Science and Technology Development Program No.20230402046GHNational Natural Science Foundation of China No. 62304222
6 · The paper itself

Abstract

The establishment of monoclonal, stably transduced cell lines is a critical step in functional genomics and drug discovery. However, conventional methods are often time-consuming, labor-intensive, and prone to compromising cell viability. Here, we present a microfluidic single-cell sorting system based on laser-induced jetting (LIJet) that significantly improves the efficiency and quality of stable cell line generation. This system integrates a light-responsive substrate with metal coating and a PDMS microfluidic chip featuring an array of microwells, enabling single-cell capture, identification, and non-contact precision release. A 532 nm nanosecond pulsed laser is used to generate localized microjets, which accurately eject target cells from the microwells. In addition to achieving a 100% sorting success rate and maintaining over 95.3% post-sorting cell viability, the system supports long-term on-chip culture and viral transduction with full real-time monitoring. We demonstrated the platform's functionality by performing on-chip ZsGreen lentiviral transduction of human lung adenocarcinoma PC9 cells, followed by fluorescence-based single-cell selection, ultimately establishing monoclonal cell lines with stable transgene expression. This platform offers notable advantages in low-damage manipulation, dynamic monitoring, and functional perturbation, providing a robust and efficient solution for the construction of stably transduced cell lines, gene function screening, and phenotypic analysis across a variety of biomedical applications.

Indexed as

Lab-On-A-Chip DevicesLasersMicrofluidic Analytical TechniquesTransduction, GeneticCell Line, TumorCell SurvivalEquipment DesignHumansLentivirusCell dynamics monitoringIn situ cell processingLaser-induced jettingMicrofluidicsSingle-cell sorting

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.