Evidence map›Paper›PMID 42063989›Full record

ArticlePhysics and imaging in radiation oncology2026

Motion mitigation in positron-emission tomography guided radiotherapy delivered on a magnetic resonance imaging-linear accelerator.

Albert J Everard, Rodrigo José Santo, Pim T S Borman, Prescilla Uijtewaal, Martin F Fast, Hugo W A M de Jong, Cornelis A T van den Berg, Bas W Raaymakers, Casper Beijst

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Albert J EverardDepartment of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100 3584 CX Utrecht, the Netherlands.
Rodrigo José SantoDepartment of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100 3584 CX Utrecht, the Netherlands.
Pim T S BormanDepartment of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100 3584 CX Utrecht, the Netherlands.
Prescilla UijtewaalDepartment of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100 3584 CX Utrecht, the Netherlands.
Martin F FastDepartment of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100 3584 CX Utrecht, the Netherlands.
Hugo W A M de JongDepartment of Radiology, University Medical Center Utrecht, Heidelberglaan 100 3584 CX Utrecht, the Netherlands.
Cornelis A T van den BergDepartment of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100 3584 CX Utrecht, the Netherlands.
Bas W RaaymakersDepartment of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100 3584 CX Utrecht, the Netherlands.
Casper BeijstDepartment of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100 3584 CX Utrecht, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Purpose: The precision of Positron Emission Tomography (PET)-guided radiotherapy may be compromised by motion. To address this, we demonstrated the feasibility of a motion-robust PET-to-magnetic resonance linear accelerator (MR-linac) pipeline. Materials and Methods: For comparison, PET images of a phantom with a target in a movable insert were acquired under a patient-derived breathing waveform and static conditions. Motion correction using the PET Maximum-Likelihood Motion and Activity (MLMA) reconstruction was compared with static reference and motion-blurred images. Targets were delineated using thresholding based on maximum standardized uptake value, and Intensity-Modulated Radiation Therapy (IMRT) plans were generated. Plans were delivered on an MR-linac with and without gating or Multi Leaf Collimator (MLC) tracking. Dosimetry was assessed using film measurements, evaluating dose differences and 3%/3 mm gamma pass rates. The pipeline was further evaluated using clinical PET data, delivered with and without gating and tracking after motion correction. Dosimetric evaluation was performed using a cylindrical multi-diode phantom. Results: Motion-blurred PET produced larger gross target volumes (GTV) (GTV: 58 cm Conclusions: A motion-robust PET-to-MR-linac pipeline using motion-corrected PET imaging and MR-guided motion mitigation is technically feasible and enhances dose precision.

Indexed as

MLC-trackingMotion MitigationMR-linacPET/CTPET-guided radiotherapy

Identifiers

PMID42063989
PMCPMC13127619

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.