ArticlePhysics and imaging in radiation oncology2026
Improving patient treatment accuracy using transit dosimetry with Electronic Portal Imaging Device images and deep learning.
Article in Physics and imaging in radiation oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and Purpose: Electronic portal imaging devices (EPID) can be utilized for transit in vivo dosimetry (IVD). A major limitation of standard amorphous Silicon EPID detectors for usage IVD is their non-linear detector response to water equivalent dose. Labor-intensive calibration and correction procedures are needed, limiting their practicality for routine clinical use. The purpose of this work was to develop a deep learning (DL) framework, based on data acquisitions and treatment planning system (TPS) dose simulations, which reconstructed water equivalent dose from transit EPID images. Materials and methods: A database of over 200 EPID measurements and corresponding portal dose simulations from the Monaco TPS was created, employing different phantoms and irradiation fields. A 2D U-Net model was developed that transforms EPID transit images into water-equivalent portal dose images. The performance was evaluated through the mean absolute error (MAE) and 2D Results: The mean MAE value over all test cases was Conclusions: Our DL framework enabled fast and accurate reconstruction of portal dose from transit EPID images. Once trained on clinical data, it may reduce complex corrections, supporting safe and effective treatments that meet modern regulatory standards.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.