Improving patient treatment accuracy using transit dosimetry with Electronic Portal Imaging Device images and deep learning.

Lorenzo Marini, Carlotta Mozzi, Michele Avanzo, Francesca Lizzi, Icro Meattini, Giovanni Pirrone, Alessandra Retico, Emmanuel Uwitonze, Aafke Christine Kraan, Cinzia Talamonti

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Lorenzo MariniDepartment of Computer Science, University of Pisa, Pisa, Italy.
Carlotta MozziDepartment of Experimental and Clinical Biomedical Sciences Mario Serio, University of Florence, Florence, Italy.
Michele AvanzoDepartment of Medical Physics, Centro di Riferimento Oncologico di Aviano (CRO) IRCCS, Aviano, Italy.
Francesca LizziNational Institute for Nuclear Physics (INFN), Pisa Division, Pisa, Italy.
Icro MeattiniDepartment of Experimental and Clinical Biomedical Sciences Mario Serio, University of Florence, Florence, Italy.
Giovanni PirroneDepartment of Medical Physics, Centro di Riferimento Oncologico di Aviano (CRO) IRCCS, Aviano, Italy.
Alessandra ReticoNational Institute for Nuclear Physics (INFN), Pisa Division, Pisa, Italy.
Emmanuel UwitonzeNational Institute for Nuclear Physics (INFN), Pisa Division, Pisa, Italy.
Aafke Christine KraanNational Institute for Nuclear Physics (INFN), Pisa Division, Pisa, Italy.
Cinzia TalamontiDepartment of Experimental and Clinical Biomedical Sciences Mario Serio, University of Florence, Florence, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Purpose: Electronic portal imaging devices (EPID) can be utilized for transit in vivo dosimetry (IVD). A major limitation of standard amorphous Silicon EPID detectors for usage IVD is their non-linear detector response to water equivalent dose. Labor-intensive calibration and correction procedures are needed, limiting their practicality for routine clinical use. The purpose of this work was to develop a deep learning (DL) framework, based on data acquisitions and treatment planning system (TPS) dose simulations, which reconstructed water equivalent dose from transit EPID images. Materials and methods: A database of over 200 EPID measurements and corresponding portal dose simulations from the Monaco TPS was created, employing different phantoms and irradiation fields. A 2D U-Net model was developed that transforms EPID transit images into water-equivalent portal dose images. The performance was evaluated through the mean absolute error (MAE) and 2D Results: The mean MAE value over all test cases was Conclusions: Our DL framework enabled fast and accurate reconstruction of portal dose from transit EPID images. Once trained on clinical data, it may reduce complex corrections, supporting safe and effective treatments that meet modern regulatory standards.

Indexed as

Deep learningEPIDRadiotherapyTransit dosimetryU-net