Evidence map›Paper›PMID 42063923›Full record

ArticleJournal of medical ultrasound

Impact of Three-dimensional-printed Skull Inserts of Different Thickness on Magnetic Resonance-guided Focused Ultrasound Heating in a Head Phantom.

Anastasia Antoniou, Leonidas Georgiou, Antreas Chrysanthou, Antonis Christofi, Yiannis Roussakis, Cleanthis Ioannides, Kyriakos Spanoudes, Jufeng Zhao, Liyang Yu, Christakis Damianou

Abstract read
In one paragraph

Article in Journal of medical ultrasound. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Anastasia AntoniouDepartment of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
Leonidas GeorgiouDepartment of Diagnostic and Interventional Radiology, German Medical Institute, Limassol, Cyprus.
Antreas ChrysanthouDepartment of Diagnostic and Interventional Radiology, German Medical Institute, Limassol, Cyprus.
Antonis ChristofiDepartment of Diagnostic and Interventional Radiology, German Medical Institute, Limassol, Cyprus.
Yiannis RoussakisDepartment of Radiation Oncology, German Medical Institute, Limassol, Cyprus.
Cleanthis IoannidesDepartment of Diagnostic and Interventional Radiology, German Medical Institute, Limassol, Cyprus.
Kyriakos SpanoudesDepartment of Veterinary Medicine, University of Nicosia School of Veterinary Medicine, Nicosia, Cyprus.
Jufeng ZhaoDepartment of Electronics and Information Engineering, Hangzhou Dianzi University, Zhejiang, China.
Liyang YuDepartment of Electronics and Information Engineering, Hangzhou Dianzi University, Zhejiang, China.
Christakis DamianouDepartment of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The application of transcranial focused ultrasound (FUS) for brain tissue ablation is limited by the significant challenges in ultrasound energy transmission through the skull. Objectives: The current study utilizes an anatomically accurate gel-filled skull phantom to investigate FUS transmission through three-dimensional (3D)-printed uniformly thin skull inserts, exploring the potential of a new therapeutic approach. Methods: The skull model was 3D printed using resin material, featuring a circular aperture for securing various skull inserts, and filled with an agar-silica gel mixture. Skull inserts of uniform thicknesses (1, 2, and 3 mm) and an anatomically accurate model featuring variable thickness, were tested. The impact of introducing each skull insert into the beam path during high-intensity FUS in the phantom was evaluated in terms of focal temperature elevation and lesion formation. These parameters were monitored through high-resolution imaging and thermometry within a 3T magnetic resonance imaging scanner. The results of sonication without skull interference served as reference. Results: FUS transmission was significantly distorted by the presence of skull inserts, with increasing thickness leading to a gradual reduction in the focal temperature. A large hyperintense lesion on T2-weighted turbo spin-echo images without skull interference diminished to a very small lesion with the 1-mm insert, while only a faint indication was observed with the 2-mm insert. However, temperature changes sufficient to cause tissue ablation were achieved using the 1-mm insert. Conclusion: The superior performance of the 1-mm resin insert suggests potential for new therapeutic applications using thin skull implants to enable FUS brain tumor ablation, pending further validation.

Indexed as

Focused ultrasoundhead phantommagnetic resonance imagingresin skull insertthicknesstranscranial

Identifiers

PMID42063923
PMCPMC13128076

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.