Evidence map›Paper›PMID 42063039›Full record

ArticleBMC musculoskeletal disorders2026

Different screw configurations for treating Sanders type IIB intra-articular calcaneal fractures: a finite element analysis.

Xian-Yu Wang, Wei-Jie Xia, Si-Yi Wang, Run-Yao Li, En-Feng Chen, Guang-Can Tan, Jian-Song Zhou, Xiao-Shan Guo, Yong-Zeng Feng

Abstract readComparative Study
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Xian-Yu WangThe Second Affiliated Hospital, Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China.
Wei-Jie XiaThe Second Affiliated Hospital, Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China.
Si-Yi WangJinggangshan University, Ji'an, China.
Run-Yao LiThe Second Affiliated Hospital, Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China.
En-Feng ChenThe Second Affiliated Hospital, Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China.
Guang-Can TanThe Second Affiliated Hospital, Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China.
Jian-Song ZhouThe Second Affiliated Hospital, Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China.
Xiao-Shan GuoThe Second Affiliated Hospital, Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China.
Yong-Zeng FengThe Second Affiliated Hospital, Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China. fengyongzeng@wmu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectivePercutaneous screw fixation (PSF) technique is widely used in treating displaced intra-articular calcaneal fractures (DIACFs), the optimal screw configuration remains controversial. In this study, a finite element analysis (FEA) was conducted to compare the biomechanical properties of five different screw configurations in the fixation of Sanders type ⅡB calcaneal fractures, aiming to provide a reference for clinical strategy selection.

methodsIn this study, models of five different screw configurations for the fixation of Sanders type IIB calcaneal fractures were constructed. After assigning material properties and applying stress, the maximum displacement and von Mises stress distribution of bone fragments and implants in each group were recorded and compared through FEA.

resultsAfter loading, the maximum displacement and von Mises stress of the bone fragments in the five models were recorded as follows: Model 1 (0.369 mm, 39.803 MPa), Model 2 (0.335 mm, 42.283 MPa), Model 3 (0.297 mm, 39.079 MPa), Model 4 (0.315 mm, 33.770 MPa), and Model 5 (0.415 mm, 41.095 MPa). The maximum displacement and stress of the screws were recorded as: Model 1 (0.286 mm, 34.439 MPa), Model 2 (0.277 mm, 35.489 MPa), Model 3 (0.233 mm, 60.152 MPa), Model 4 (0.247 mm, 38.725 MPa), and Model 5 (0.330 mm, 46.806 MPa), Model 3 exhibiting the best mechanical performance, while Model 5 showed the least favorable performance.

conclusionsFEA results demonstrate that the use of multiple sustentaculum tali screws and a "kickstand" screw to enhance fixation of the posterior articular surface, along with longitudinal screws inserted superior to the Achilles tendon insertion contributed to stability. The longitudinal screws inserted from the calcaneal tuberosity provide relatively poor stability. Additionally, reinforcing the fixation of the medial column of the calcaneus enhances stability.

Indexed as

Bone ScrewsCalcaneusFinite Element AnalysisFracture Fixation, InternalIntra-Articular FracturesBiomechanical PhenomenaHumansStress, MechanicalBiomechanical StabilityFinite Element AnalysisIntra-articular Calcaneal FracturesPercutaneous Screw Fixation

Identifiers

PMID42063039
PMCPMC13262330

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.