Evidence map›Paper›PMID 42062636›Full record

ArticleThe Saudi dental journal2026

Effect of simulated bur radius compensation on full-contour CAD crown morphology and trueness across tooth types. An in- silico study.

Nabeel S Martani

Abstract read
In one paragraph

Article in The Saudi dental journal, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Nabeel S MartaniCollege of Dentistry, Hawler Medical University, Erbil, Iraq. nabeel.martani@hmu.edu.krd.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To systematically investigate and quantify the influence of bur radius compensation size on the design parameters of full-contour computer-aided design (CAD) crowns. The study analyzes the deterministic trends in morphological characteristics, surface area, volume, and geometric trueness across varying tooth anatomies to provide data-driven guidelines for CAD protocols. This study utilized a deterministic computer simulation to generate idealized virtual crown designs for three distinct anatomical tooth types (molar [#3], premolar [#5], and central incisor [#8]). Because the computational algorithm yields identical outputs from identical inputs with zero variance, a sample size calculation was not applicable; instead, single standardized designs were analyzed. The crowns were processed with seven varying bur radius settings: a 0.00 mm baseline (representing an ideal design with no bur constraints) and six test radii ranging from 0.10 mm to 1.50 mm. The resulting standard tessellation language (STL) files were analyzed using a custom Python algorithm (Eyleen Code) by utilizing Trimesh and NumPy libraries, to calculate trend geometric deviation metrics Root Mean Squared Error (RMSE) and Hausdorff Distance (H.D) relative to the baseline. The simulation data revealed that increasing the bur radius from 0.10 mm to 1.50 mm resulted in progressive morphological changes across all tooth types. A marked trend of volumetric loss was observed; the molar volume decreased from a baseline of 160.60 mm

Indexed as

Bur RadiusComputer-Aided Design (CAD)Dental CrownsGeometric TruenessSurface Morphology