ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2026
Wavefront Line-Scan Imaging Via a Single-Pixel Detector.
Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Wavefront single-pixel imaging (WSPI) has emerged as a promising approach for simultaneous amplitude and phase reconstruction, especially in spectral wavebands where cameras are immature or even unavailable. However, conventional WSPIs suffer from limited imaging speed & range, and heavy pattern-data storage. Here, we demonstrate a wavefront line-scan imaging (WLSI) technique that integrates 1D spatial light modulation with single-pixel detection, enabling faster imaging in a large rectangular range with minimal pattern-data storage. A theoretical model is developed and validated by simulations and experiments. A digital micromirror device (DMD) worked in 1D, achieving a modulation rate of 90.9 kHz, enabling line-scan imaging at 2.8 ms per line without compressive down-sampling. Consequently, the WLSI achieves over 4-fold enhancement in imaging speed and significantly reduces the pattern-data storage to more than 5 orders of magnitude as compared to the WSPI, when reconstructing a wavefront of 256 × 256 pixels at full sampling. The push-broom WLSI extends the imaging range, enabling continuous acquisition in a long rectangular range. Combining the advantages of WSPI with the flexibility of line-scan imaging, we offer a potential solution for high-throughput amplitude and phase imaging of biological samples, defect detection of optical components, wavefront detection in special spectra, etc.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.