Evidence map›Paper›PMID 42058154›Full record

ArticlePhysics and imaging in radiation oncology2026

Landmark-guided deformable image registration for accurate cumulative dose evaluation in lung reirradiation.

Marija Popovic, Marco di Francesco, Neil Kopek, Georges Al Makdessi, Monica Serban

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Marija PopovicMedical Physics Unit, Department of Oncology, McGill University, 1001 Bd Décarie, Montreal, QC H4A 0B1, Canada.
Marco di FrancescoMedical Physics Unit, Department of Oncology, McGill University, 1001 Bd Décarie, Montreal, QC H4A 0B1, Canada.
Neil KopekRadiation Oncology, Department of Oncology, McGill University, 1001 Bd Décarie, Montreal, QC H4A 0B1, Canada.
Georges Al MakdessiRadio-Oncologie, Hopital de Rouyn-Noranda, 4 9e Rue, Rouyn-Noranda, QC J9X 2B2, Canada.
Monica SerbanMedical Physics Unit, Department of Oncology, McGill University, 1001 Bd Décarie, Montreal, QC H4A 0B1, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Dose summation in thoracic reirradiation is challenging due to anatomical changes and limitations of rigid image registration. Deformable image registration offers improved accuracy but requires careful evaluation before clinical implementation. This work aimed to develop and validate a clinically applicable workflow for deformable image registration-assisted dose accumulation in thoracic reirradiation. Materials and methods: Registration accuracy was evaluated using a digital phantom and 21 thoracic reirradiation clinical cases. Two deformable registration methods were assessed within progressively focused regions of interest. Registration accuracy was quantified using the American Association of Physicists in Medicine (AAPM) Task Group TG 132-recommended metrics, including target registration error, Dice similarity coefficient, mean distance-to-agreement, and Jacobian determinant. Cumulative dose volume metrics expressed as equivalent dose in 2 Gy fractions were calculated and compared between deformable and rigid image registration-based accumulation for relevant organs of interest. Results: Landmark-guided deformable registration using ten anatomical guiding landmarks within the irradiated lung volume (defined by the 10% isodose) with an additional 12.5 mm cranio-caudal margin, achieved the highest registration accuracy, meeting TG-132 quality tolerances in 18 of 21 cases. Compared with rigid registration, deformable image registration-based dose accumulation resulted in statistically significant differences in lung dose-volume metrics, including mean dose, V20 Gy and critical volume CV12.5 Gy (all p < 0.01). Conclusions: Patient-specific deformable image registration using landmark guidance within targeted regions improved the accuracy of cumulative dose-volume metrics in thoracic reirradiation compared to rigid image registration. This validated workflow is feasible for clinical implementation and supports individualized reirradiation planning.

Indexed as

Deformable image registrationDose accumulationDose mappingLungReirradiationRigid image registration

Identifiers

PMID42058154
PMCPMC13123574

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.