ArticleJournal of applied clinical medical physics2026

Intersoftware variability in SPECT quality control: A technical note on analytical discrepancies and compliance decisions.

Feng Jiawu, Zhang Li, Wang Shaojia, Liu Fei, Chen Yuhang, Peng Huaguang, Zhou Xuan, Cheng Yongliang, Sun Jingzhi

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Feng JiawuHubei Provincial Hospital of Integrated Chinese & Western Medicine (Hubei Provincial Hospital for Occupational Disease), Wuhan, China.
Zhang LiHubei Provincial Hospital of Integrated Chinese & Western Medicine (Hubei Provincial Hospital for Occupational Disease), Wuhan, China.
Wang ShaojiaHubei Provincial Hospital of Integrated Chinese & Western Medicine (Hubei Provincial Hospital for Occupational Disease), Wuhan, China.
Liu FeiHubei Provincial Hospital of Integrated Chinese & Western Medicine (Hubei Provincial Hospital for Occupational Disease), Wuhan, China.
Chen YuhangHubei Provincial Hospital of Integrated Chinese & Western Medicine (Hubei Provincial Hospital for Occupational Disease), Wuhan, China.
Peng HuaguangHubei Provincial Hospital of Integrated Chinese & Western Medicine (Hubei Provincial Hospital for Occupational Disease), Wuhan, China.
Zhou XuanHubei Provincial Hospital of Integrated Chinese & Western Medicine (Hubei Provincial Hospital for Occupational Disease), Wuhan, China.
Cheng YongliangWuhan Prevention and Treatment Center for Occupational Diseases, Wuhan, China.
Sun JingzhiHubei Provincial Hospital of Integrated Chinese & Western Medicine (Hubei Provincial Hospital for Occupational Disease), Wuhan, China.

Funding

Hubei Preventive Medicine Association "Health Innovation Talent Cultivation Action 2025SWGKY143Hubei Provincial Hospital of Integrated Chinese & Western Medicine "Three Major Projects" Program GG202514
6 · The paper itself

Abstract

backgroundQuality control (QC) is essential for ensuring the diagnostic reliability of Single-Photon Emission Computed Tomography (SPECT) systems. However, the reliance on third-party software for analyzing QC metrics introduces a potential source of variability that is not yet standardized. Variability in QC results due to the use of different image analysis software may compromise both equipment evaluation and interinstitutional comparability. PURPOSE: This technical note assessed the variability in QC test results generated by different SPECT image analysis software packages to underscore the need for improved standardization.

methodsFive representative commercial SPECT QC software packages (A-E) were used to analyze identical DICOM image sets acquired from four SPECT/CT systems in accordance with the WS 523-2019 standard. Evaluated metrics included file reading success rates, key performance indicators (intrinsic uniformity, resolution, linearity), and compliance rates. Statistical analysis employed ANOVA or Welch's tests, followed by LSD post hoc testing, with effect sizes (η

resultsFile reading success varied significantly (61.8%-100%), with Softwares B and D exhibiting higher failure rates. Compliance rates for identical devices varied considerably (68.8%-100%). Statistically significant intersoftware differences were found for intrinsic integral uniformity (F = 10.17, p < 0.05, η

conclusionWe found significant disparities between software packages in both file reading capability and the analysis of key QC performance indicators. These differences directly impact the accuracy of equipment performance evaluations and interinstitutional comparability, potentially leading to divergent conclusions regarding the same device's compliance status.

Indexed as

Image Processing, Computer-AssistedPhantoms, ImagingQuality Assurance, Health CareQuality ControlSoftwareTomography, Emission-Computed, Single-PhotonHumansReproducibility of Resultsimage analysis softwarequality controlSPECTstandardizationvariability

Identifiers

PMID42055798
PMCPMC13128317

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.