ArticleAnnals of biomedical engineering2026
Temperature Effects on the Impact Attenuation Performance of American Football Helmets and Padding Materials.
Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
While American football games are played across a wide range of temperatures, current helmet rating protocols assess performance primarily at room temperature. This study evaluates how temperature influences impact attenuation performance of American football helmets and their padding systems. Six top-ranked NFL helmet models and their padding units were tested at four controlled temperatures (- 10, 5, 23, and 38 °C). Padding units were evaluated using drop tests (4.9 kg, 2.4 m/s) to measure peak acceleration, transmitted force, strain, and impact duration. Helmets were tested using a linear impactor (15.6 kg, 5.5 m/s) with a Hybrid III headform instrumented for measuring head peak linear accelerations (PLA) and angular velocities (PAV). Head injury criterion (HIC) and DAMAGE metrics were also calculated. Colder conditions (- 10, 5 °C), compared to room temperature (23 °C), stiffened padding responses, significantly increasing peak acceleration and transmitted force by up to 307% and 331%, respectively, while reducing strain and impact duration in drop testing. Similarly, helmet tests showed significant increases up to 56%, 44%, 86%, and 23% in PLA, PAV, HIC, and DAMAGE, respectively, compared to 23 °C. Warm conditions (38 °C) softened padding materials, producing significantly higher strain and impact durations by up to 38% and 56%, respectively, while helmet-level responses showed no significant change across head kinematic or injury metrics, compared to 23 °C. These findings demonstrate that temperature can influence impact attenuation performance of helmets. Incorporating more comprehensive temperature-dependent evaluation into helmet design and rating protocols is essential, ensuring consistent protection across diverse environmental conditions.
Indexed as
Identifiers
42053765What OpenQuestion holds
Registered trials