ArticleJBMR plus2026
Effects of contrast on opportunistic computed tomography vertebral bone mineral density analysis using internal calibration.
Article in JBMR plus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Opportunistic CT, which repurposes clinical CT scans, has the potential to aid in osteoporosis screening and diagnosis. To convert CT scans to bone-equivalent densities without a calibration phantom, internal (or phantomless) calibration methods have been developed, using referent tissues of known density within the body. A key limitation is that intravenous iodinated contrast enhancement, which is routinely used in clinical settings, impacts quantitative measurements derived from these phantomless calibration techniques. Therefore, this cross-sectional study examined the influence of contrast enhancement on internal reference tissues and volumetric BMD (vBMD) measures derived using phantomless internal calibration. Hematuria protocol CT scans (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.