ArticleClinical implant dentistry and related research2026
Robotic Quad Zygomatic Implant Surgery Accuracy Ex Vivo With a New Semi-Autonomous Optically-Driven Haptic System.
Article in Clinical implant dentistry and related research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo evaluate ex vivo accuracy of robotic computer-assisted implant surgery (r-CAIS) for quad zygomatic implant (ZI) placement with a novel semi-autonomous, optically-driven, haptic-assisted system.
methodsTwo expert operators placed ZIs in human cadavers. Accuracy was evaluated by superimposing pre- and post-operative cone-beam computed tomography (CBCT) scans, measuring linear (mm) on the x-, y-, and z- axes and angular (degrees) deviations. Sample size was calculated. The main analysis focused on composite outcomes (global platform, global apical, and angular deviation), while extended analyses examined deviations on individual spatial axes (buccal-lingual, mesial-distal, depth, and non-depth) for both implant platform and apex. Three multivariate models were executed on global platform, global apical, and angular deviation considering implant position (anterior vs. posterior) and quadrant (left vs. right).
resultsForty ZIs were placed in 10 human cadavers. The mean global deviations at implant platform and apex were 1.16 mm (standard deviation (SD) 0.47) and 1.51 mm (SD 0.70), with mean angular deviation of 1.04° (SD 0.65°). In the multivariate models, implant position was found to be significant for global platform deviation (p = 0.0218), with posterior implants performing better, and for angular deviation (p = 0.0465), with anterior implants performing better.
conclusionThe optically driven haptic-assisted robotic system demonstrated high accuracy in quad ZI surgery, with all implants placed without intraoperative complications or significant errors impacting adjacent anatomical structures. Mean global linear deviations of 1 and 1.5 mm at platform and apex, and 1° of angular deviation were experienced. Further research is necessary to validate these promising results in vivo.