Evidence map›Paper›PMID 42051046›Full record

ArticleClinical implant dentistry and related research2026

Robotic Quad Zygomatic Implant Surgery Accuracy Ex Vivo With a New Semi-Autonomous Optically-Driven Haptic System.

Alessandro Pozzi, James Chow, Andrea Laureti, Lorenzo Arcuri, Ilaria Cammarota, Alessandra Nardi, Hom-Lay Wang

Abstract read
In one paragraph

Article in Clinical implant dentistry and related research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Alessandro PozziDepartment of Clinical Science and Translational Medicine, University of Rome Tor Vergata, Rome, Italy.ORCID https://orcid.org/0000-0002-3052-8186
James ChowBrånemark Osseointegration Centre, Hong Kong, People's Republic of China.ORCID https://orcid.org/0000-0002-2966-0067
Andrea LauretiDepartment of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy.ORCID https://orcid.org/0000-0003-0217-7101
Lorenzo ArcuriDepartment of Life Science, Health and Health Professions, Link Campus University, Rome, Italy.ORCID https://orcid.org/0000-0002-6152-3337
Ilaria CammarotaDepartment of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy.
Alessandra NardiDepartment of Mathematics, University of Rome "Tor Vergata", Rome, Italy.
Hom-Lay WangDepartment of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, USA.ORCID https://orcid.org/0000-0003-4238-1799

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo evaluate ex vivo accuracy of robotic computer-assisted implant surgery (r-CAIS) for quad zygomatic implant (ZI) placement with a novel semi-autonomous, optically-driven, haptic-assisted system.

methodsTwo expert operators placed ZIs in human cadavers. Accuracy was evaluated by superimposing pre- and post-operative cone-beam computed tomography (CBCT) scans, measuring linear (mm) on the x-, y-, and z- axes and angular (degrees) deviations. Sample size was calculated. The main analysis focused on composite outcomes (global platform, global apical, and angular deviation), while extended analyses examined deviations on individual spatial axes (buccal-lingual, mesial-distal, depth, and non-depth) for both implant platform and apex. Three multivariate models were executed on global platform, global apical, and angular deviation considering implant position (anterior vs. posterior) and quadrant (left vs. right).

resultsForty ZIs were placed in 10 human cadavers. The mean global deviations at implant platform and apex were 1.16 mm (standard deviation (SD) 0.47) and 1.51 mm (SD 0.70), with mean angular deviation of 1.04° (SD 0.65°). In the multivariate models, implant position was found to be significant for global platform deviation (p = 0.0218), with posterior implants performing better, and for angular deviation (p = 0.0465), with anterior implants performing better.

conclusionThe optically driven haptic-assisted robotic system demonstrated high accuracy in quad ZI surgery, with all implants placed without intraoperative complications or significant errors impacting adjacent anatomical structures. Mean global linear deviations of 1 and 1.5 mm at platform and apex, and 1° of angular deviation were experienced. Further research is necessary to validate these promising results in vivo.

Indexed as

Dental Implantation, EndosseousRobotic Surgical ProceduresSurgery, Computer-AssistedZygomaCadaverCone-Beam Computed TomographyFemaleHumans

Identifiers

PMID42051046
PMCPMC13125970

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.