Evidence map›Paper›PMID 42045582›Full record

ArticleEuropean radiology experimental2026

Photon-counting CT for dynamic lung perfusion: validation of a low-dose protocol in a porcine lung transplantation model.

Anna M Hunkemöller, Thomas Werncke, Julian Dittrich, Cornelia Schaefer-Prokop, Franz Söbbeler, Murat Avsar, Jawad Salman, Arjang Ruhparwar, Rainer Blasczyk, Sevval Besli and 4 more

Abstract readValidation Study
In one paragraph

Article in European radiology experimental, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Anna M HunkemöllerInstitute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany. hunkemoeller.anna@mh-hannover.de.
Thomas WernckeInstitute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany.
Julian DittrichInstitute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany.
Cornelia Schaefer-ProkopDepartment of Radiology, Radboud University, Geert Grooteplein Zuid 32, Nijmegen, 6525 GA, The Netherlands.
Franz SöbbelerInstitute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany.
Murat AvsarDepartment of Cardiothoracic, Transplant and Vascular Surgery, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany.
Jawad SalmanDepartment of Cardiothoracic, Transplant and Vascular Surgery, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany.
Arjang RuhparwarDepartment of Cardiothoracic, Transplant and Vascular Surgery, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany.
Rainer BlasczykInstitute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany.
Sevval BesliInstitute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany.
Constanca FigueiredoInstitute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany.
Alicia Enzig-StrohmInstitute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany.
Frank K WackerInstitute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany.
Hoen-Oh ShinInstitute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30655, Hannover, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivePhoton-counting CT (PCCT) combines improved dose efficiency with spectral imaging, enabling dynamic functional imaging at chest CT dose levels. Dual energy CT typically uses perfused blood volume (PBV) as a static perfusion surrogate. This study compared low-dose dynamic PCCT compared with reference-dose PCCT and static PBV imaging. MATERIALS AND

methodsSix minipigs with left lung transplants underwent dynamic perfusion imaging using PCCT at reference and low-dose settings, along with a static PBV scan. Perfusion metrics-Blood Flow Deconvolution (BFD), Mean Transit Time Deconvolution (MTTD), Flow Extraction Product (FEP), and Time to Start Deconvolution (TTSD)-were normalized and analyzed across six lung regions using Kruskal-Wallis tests and Bland-Altman analysis.

resultsLow-dose and reference-dose dynamic PCCT showed strong agreement across perfusion parameters (BVP bias: 0.03; BVD bias: 0.04), with no significant differences in BVP (p = 0.995) or BVD (p = 0.374). Kinetic metrics were stable across dose levels (all p > 0.2). While low-dose imaging showed slightly greater perfusion heterogeneity, BVP remained robust. Static PBV differed significantly from dynamic BVP (reference dose: p < 0.001; low-dose: p = 0.04). Left-right perfusion differences were detected in two animals by all methods. Estimated doses were 2.37 mSv (reference-dose) and 1.36 mSv (low-dose), comparable to chest CT (1.49 mSv) and below conventional CT perfusion (3-10 mSv).

conclusionDynamic PCCT enables quantitative lung perfusion imaging at radiation doses comparable to standard chest CT. Low-dose dynamic PCCT shows strong agreement with reference-dose acquisitions, while dynamic parameters reveal functional differences not captured by static PBV imaging. RELEVANCE STATEMENT: Dynamic low-dose photon-counting computed tomography enables lung perfusion quantification at radiation doses comparable to standard chest CT, facilitating dose-efficient functional imaging in pulmonary disease. KEY POINTS: Low-dose PCCT (~ 1.36 mSv) is feasible, comparable to single chest CT (1.49 mSv). Strong agreement was seen between low- and reference-dose PCCT (BVP bias 0.03; BVD bias 0.04). Kinetic perfusion metrics remained stable across dose levels (all p > 0.2).

Indexed as

LungLung TransplantationPerfusion ImagingTomography, X-Ray ComputedAnimalsModels, AnimalPhotonsRadiation DosageSwineSwine, MiniatureDynamic lung perfusionLow-dose CTPhoton-counting CTPulmonary transplantation modelQuantitative perfusion imaging

Identifiers

PMID42045582
PMCPMC13121657

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.