Evidence map›Paper›PMID 42043988›Full record

ArticleIEEE transactions on medical imaging2026

Spatial-Jitter Model for Magnetoencephalography Sensor Arrays.

Joonas Iivanainen

Abstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Joonas Iivanainen

Funding

Scalable Software for Distributed Processing and Visualization of Multi-Site MEG/EEG DatasetsR01NS104585 · NINDS · MASSACHUSETTS GENERAL HOSPITAL · PI MATTI HAMALAINEN · 2018 to 2026
$4.3M
NINDS NIH HHS R01 NS104585
6 · The paper itself

Abstract

Sampling jitter, i.e., random deviations in the time instants when samples are taken, causes frequency-dependent noise that reduces signal-to-noise ratio (SNR). This paper generalizes the concept of jitter to magnetoencephalography (MEG) sensor arrays that spatially sample the quasistatic magnetic field due to brain activity. It is shown that spatial jitter, i.e., random deviations in MEG sensor positions, causes spatial-frequency-dependent noise in the vector spherical harmonics domain that reduces the attainable SNR and spatial resolution in MEG. Similarly, the paper also considers noise due to random sensor orientation errors ('orientation jitter') and errors due to field integration by the finite-sized sensors ('aperture error'). The analysis in this paper shows that on-scalp MEG measurements taken closer to the head are more resistant to spatial and orientation jitter at high spatial frequencies than off-scalp measurements taken further away. On the other hand, on-scalp measurements are affected more by aperture errors than off-scalp measurements. The paper also provides new insights to the effect of sensor noise on the spatial resolution of on- and off-scalp sensor arrays using a novel normalization of the vector spherical harmonics. The paper also simulates spatial-jitter phenomena with realistic sensor arrays based on optically pumped magnetometers and superconducting quantum interference device sensors. This realistic simulation shows that spatial jitter reduces SNR and affects how the measurements should be regularized in order to maximize SNR.

Indexed as

MagnetoencephalographyModels, NeurologicalSignal Processing, Computer-AssistedAlgorithmsBrainComputer SimulationHumansSignal-To-Noise Ratio

Identifiers

PMID42043988
PMCPMC13503295

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.