In one paragraph

Article in International journal of computer assisted radiology and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Harry Robertshaw *Surgical & Interventional Engineering, School of Biomedical Engineering & Imaging Sciences, Kings College London, London, UK.
Yanghe Hao *Surgical & Interventional Engineering, School of Biomedical Engineering & Imaging Sciences, Kings College London, London, UK.
Weiyuan DengSurgical & Interventional Engineering, School of Biomedical Engineering & Imaging Sciences, Kings College London, London, UK.
Benjamin JacksonSurgical & Interventional Engineering, School of Biomedical Engineering & Imaging Sciences, Kings College London, London, UK.
S M Hadi SadatiSchool of Engineering & Materials Science, Queen Mary London, London, UK.
Nikola FischerSurgical & Interventional Engineering, School of Biomedical Engineering & Imaging Sciences, Kings College London, London, UK.
Tom VercauterenSurgical & Interventional Engineering, School of Biomedical Engineering & Imaging Sciences, Kings College London, London, UK.
Alejandro GranadosSurgical & Interventional Engineering, School of Biomedical Engineering & Imaging Sciences, Kings College London, London, UK.
Thomas C BoothSurgical & Interventional Engineering, School of Biomedical Engineering & Imaging Sciences, Kings College London, London, UK. thomas.booth@kcl.ac.uk.

Funding

Engineering and Physical Sciences Research Council EP/R513064/1MRC IAA 2021 Kings College London MR/X502923/1Wellcome TrustWellcome Trust 203148/A/16/Z
6 · The paper itself

Abstract

purposeMechanical thrombectomy (MT) improves stroke outcomes, but is limited by a lack of local treatment access. Widespread distribution of reinforcement learning (RL)-based robotic systems can be used to alleviate this challenge through autonomous navigation, but current RL methods require live device tip coordinate tracking to function. This paper aims to develop and evaluate a real-time catheter tip tracking pipeline under fluoroscopy, addressing challenges such as low contrast, noise, and device occlusion.

methodsA multi-threaded pipeline was designed, incorporating frame reading, preprocessing, inference, and post-processing. Deep learning segmentation models, including U-Net, U-Net+Transformer, and SegFormer, were trained and benchmarked using two-class and three-class formulations. Post-processing involved two-step component filtering, one-pixel medial skeletonization, and greedy arc-length path following with contour fall-back.

resultsOn manually labeled moderate complexity fluoroscopic video data, the two-class SegFormer achieved a mean absolute error of 4.44 mm, outperforming U-Net (4.60 mm), U-Net+Transformer (6.20 mm) and all three-class models (5.19-7.74 mm). On segmentation benchmarks, the system exceeded state-of-the-art CathAction results with improvements of up to +5% in Dice scores for three-segmentation.

conclusionThe results demonstrate that the proposed multi-threaded tracking framework maintains stable performance under challenging imaging conditions, outperforming prior benchmarks, while providing a reliable and efficient foundation for RL-based autonomous MT navigation.

Indexed as

Deep LearningStrokeThrombectomyAutonomous RobotsCathetersFluoroscopyHumansReinforcement Machine LearningCatheter tip trackingDeep learning segmentationFluoroscopyMechanical thrombectomy

Identifiers

PMID42043651
PMCPMC13354667

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.