Evidence map›Paper›PMID 42043538›Full record

ArticleAbdominal radiology (New York)2026

Normal liver stiffness values measured with MR elastography and two-dimensional shear wave elastography in children aged 9-17 years.

Mehmet Seker, Mehmet Sait Dogan, Hayrettin Temel, Osman Kahraman, Fatma Zeynep Gungoren, Mehmet Kocak, Cengiz Erol

Abstract read
PubMed Publisher
In one paragraph

Article in Abdominal radiology (New York), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mehmet SekerDepartment of Radiology, Istanbul Medipol University, School of Medicine, Istanbul, Turkey.
Mehmet Sait DoganDepartment of Radiology, Istanbul Medipol University, School of Medicine, Istanbul, Turkey.
Hayrettin TemelDepartment of Pediatrics, Istanbul Medipol University, School of Medicine, Istanbul, Turkey.
Osman KahramanDepartment of Radiology, Istanbul Medipol University, School of Medicine, Istanbul, Turkey. osmnkhrmn2017@gmail.com.
Fatma Zeynep GungorenDepartment of Radiology, Anadolu Medical Center In Affiliation with Johns Hopkins Medicine, Istanbul, Turkey.
Mehmet KocakDepartment of Biostatistics, Istanbul Medipol University, School of Medicine, Istanbul, Turkey.
Cengiz ErolDepartment of Radiology, Istanbul Medipol University, School of Medicine, Istanbul, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to establish pediatric reference ranges for liver stiffness measured by magnetic resonance elastography (MRE) and two‑dimensional shear‑wave ultrasound elastography (2D‑SWE) in healthy Turkish children aged 9-17 years. MATERIALS AND

methodsOf the 100 initially recruited volunteers, nine were excluded based on strict imaging and biochemical criteria. A final cohort of 91 healthy participants with normal clinical, biochemical, and serological evaluation underwent same‑day MRE (3.0 T, external 60 Hz pneumatic active driver, anterior passive driver paddle over the right upper quadrant, breath‑hold acquisition; non‑vascular ROIs in the right lobe) and 2D‑SWE (intercostal approach, supine position, right arm elevated, 3-5 circular ROIs placed 1.5-2.0 cm below the liver capsule in the right lobe, during end‑expiration breath‑hold). Reference intervals were calculated as mean ±1.96 SD and represent modality‑specific reference limits. Group comparisons were evaluated using the Wilcoxon-Mann-Whitney and Kruskal-Wallis tests.

resultsMean liver stiffness values (LSV) were 2.16 ± 0.24 kPa for MRE (reference interval 1.69-2.63 kPa) and 5.34 ± 1.00 kPa for 2D‑SWE (reference interval 3.38-7.30 kPa). No significant differences were observed across age groups (9-11, 12-14, 15-17 years) or between sexes. Correlations with laboratory values were limited and clinically non‑significant in this healthy cohort.

conclusionSame‑day MRE and 2D‑SWE provide modality‑specific pediatric liver stiffness reference ranges in healthy children aged 9-17 years. These values appear independent of age and sex and should be interpreted as non‑interchangeable, modality‑dependent reference intervals.

Indexed as

Elasticity Imaging TechniquesLiverMagnetic Resonance ImagingAdolescentChildFemaleHumansMaleReference ValuesTurkeyHealthy childrenLiver stiffness measurementMagnetic resonance elastographyUltrasound elastography

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.