Evidence map›Paper›PMID 42042937›Full record

ArticleTomography (Ann Arbor, Mich.)2026

Standardized Images and Evaluation Metrics for Tomography.

Anna Frixou, Theodoros Leontiou, Efstathios Stiliaris, Costas N Papanicolas

Abstract read
In one paragraph

Article in Tomography (Ann Arbor, Mich.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Anna FrixouThe Cyprus Institute, 2121 Nicosia, Cyprus.ORCID 0009-0009-2658-8002
Theodoros LeontiouDepartment of Mechanical Engineering, Frederick University, 1036 Nicosia, Cyprus.ORCID 0000-0002-4623-2486
Efstathios StiliarisThe Cyprus Institute, 2121 Nicosia, Cyprus.ORCID 0000-0001-9496-7762
Costas N PapanicolasThe Cyprus Institute, 2121 Nicosia, Cyprus.ORCID 0000-0001-5320-0768

Funding

Innovation Foundation under the project PERSPECT EXCELLENCE/0524/0410),
6 · The paper itself

Abstract

BACKGROUND/

objectivesModern tomographic reconstruction methods-including physics-informed and AI-based approaches-can produce very high fidelity images. In this regime, widely used global image quality metrics often approach saturation, making it harder to distinguish residual differences between methods and identify remaining performance gaps. This study introduces a physically grounded and standardized evaluation framework designed to retain sensitivity beyond conventional global metrics and support both comparison and systematic improvement in tomographic reconstruction methods.

methodsThe proposed framework defines standardized reference images-"Source", "Detector", "Ideal", and "Realistic"-using Monte Carlo simulations, with the Ideal Image serving as a physically grounded benchmark. Reconstruction performance is evaluated using pixel-wise difference and χ2 maps, Region-of-Interest analysis, intensity (gray-value) histogram comparisons, and the Structure and Contrast Index (SCI), computed on difference maps. Demonstrations use simulated SPECT data reconstructed with ART, MLEM, and RISE-1.

resultsAcross case studies, SCI and χ2-based diagnostics reveal structured residuals and localized deficiencies not evident from global similarity metrics such as SSIM or NMSE. Comparative analyses show that methods with similar global scores can exhibit distinct residual structures and region-specific performance variations, while improved agreement in the sinogram domain does not necessarily translate into improved image fidelity. Histogram-based diagnostics provide complementary information on intensity redistribution not captured by pixel-domain summaries.

conclusionsThe framework provides a reproducible, physically meaningful, and sensitive approach for evaluating tomographic reconstruction performance in the high-fidelity regime. By combining standardized reference images with multi-domain and multi-metric analysis, it enables robust benchmarking and supports physically consistent interpretation of reconstruction quality.

Indexed as

Image Processing, Computer-AssistedTomography, Emission-Computed, Single-PhotonAlgorithmsHumansMonte Carlo MethodPhantoms, Imagingevaluation of reconstruction methodsimage reconstructionMLEMreconstruction algorithmsRISEtomography

Identifiers

PMID42042937
PMCPMC13120552

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.