Evidence map›Paper›PMID 42042297›Full record

ArticleJournal of functional biomaterials2026

Using Citric-Acid-Based Anodization to Form Magnesium-Doped Carbonated Apatite-Containing Oxides on Solid and 3D-Printed Titanium Substrates.

Amisha Parekh, Arunendu Ettuthaiyil Sambasivan, Mikyle Paul, Arash Soltani, Aya Ali, John Tucker, Jonathan W Pegues, Nima Shamsaei, Amol V Janorkar, Michael D Roach

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Amisha ParekhDepartment of Biomedical Materials Science, University of Mississippi Medical Center, Jackson, MS 39216, USA.ORCID 0000-0002-3478-4806
Arunendu Ettuthaiyil SambasivanDepartment of Biomedical Materials Science, University of Mississippi Medical Center, Jackson, MS 39216, USA.
Mikyle PaulDepartment of Mechanical Engineering, Auburn University, Auburn, AL 36849, USA.ORCID 0000-0001-9276-7361
Arash SoltaniDepartment of Mechanical Engineering, Auburn University, Auburn, AL 36849, USA.ORCID 0000-0002-2025-6359
Aya AliDepartment of Biomedical Materials Science, University of Mississippi Medical Center, Jackson, MS 39216, USA.ORCID 0000-0001-7006-0322
John TuckerDepartment of Biomedical Materials Science, University of Mississippi Medical Center, Jackson, MS 39216, USA.
Jonathan W PeguesDepartment of Mechanical Engineering, Auburn University, Auburn, AL 36849, USA.ORCID 0000-0002-5218-7597
Nima ShamsaeiDepartment of Mechanical Engineering, Auburn University, Auburn, AL 36849, USA.
Amol V JanorkarDepartment of Biomedical Materials Science, University of Mississippi Medical Center, Jackson, MS 39216, USA.
Michael D RoachDepartment of Biomedical Materials Science, University of Mississippi Medical Center, Jackson, MS 39216, USA.ORCID 0000-0002-8250-4610

Funding

University of Mississippi Medical Center Intramural Grant DN00554
6 · The paper itself

Abstract

With increasing life expectancy and an aging global population, the demand for orthopedic and dental implants is increasing. Recently developed, citric-acid-based anodization processes facilitate the production of more bioactive oxide layers by incorporating important bone minerals such as Ca, P, and Mg and forming bone-like crystalline compounds such as carbonated apatite on titanium implant materials. The primary goal of the present study was to evaluate the applicability of these anodization processes to solid and 3D-printed titanium alloy substrates. The anodized oxides produced on each solid or 3D-printed lattice substrate revealed multi-scaled surface roughness profiles as evidenced by scanning electron microscopy, optical microscopy, and surface roughness analyses. Additionally, each oxide group was shown to incorporate substantial amounts of Ca, P, and Mg bone-mineral dopants and form AB-type carbonated apatite, as shown using a combination of energy-dispersive spectroscopy, X-ray photoelectron spectroscopy, X-ray diffraction, and attenuated total reflectance-Fourier transform infrared spectroscopy analyses. Finally, each oxide group showed sustained Ca, P, and Mg ion release during an inductively coupled plasma spectroscopy dissolution assessment, and demonstrated early apatite-forming ability during simulated body fluid bioactivity testing. The findings of this study show much promise for the applicability of these novel oxide coatings to a wide variety of future titanium implant applications.

Indexed as

3D-printedanodizationbioactivitybonehydroxyapatiteimplantsion releasestress shieldingsurface modificationtitanium

Identifiers

PMID42042297
PMCPMC13117176

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.