ArticleBiomimetics (Basel, Switzerland)2026
An Experimental Measurement Method to Characterize and Apply Platinum Silicon Material for a Biomechanical Replica of the Thoracic Aorta.
Article in Biomimetics (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Currently, silicone is a common material used in medical research and biomedical applications. This research aims to characterize extra-soft platinum silicone (shore A 00 50) and compare its mechanical behavior with that of the human thoracic aorta. By developing molds to get samples, for tensile testing according to ISO 37 and ASTM D412, and for compression testing according to ISO 7743 and ASTM D575, using a universal testing machine for tensile and compression tests, and applying digital image correlation (DIC) algorithms, the mechanical properties were characterized in a total of 10 tensile samples and 6 compression samples. The results show an ultimate tensile strength up to 1.77 ± 0.12 MPa in the ASTM samples and 2.10 ± 0.14 MPa in the ISO samples; alongside an incremental elastic module of 80.08 ± 7.94 kPa and 117.98 ± 11.39 kPa; finally, an elongation at break of 1114.49 ± 76.77% and 936.08 ± 63.56%, corresponding to the values of a healthy thoracic aorta. The replica of the thoracic aorta in this material was developed by a brush method, with a thickness of 1.82 mm, a length from the aortic arch to the descending aorta of 200.49 mm, and diameters of 20.45 and 16.05 mm for the ascending and descending aorta, respectively.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.