ArticleBiomimetics (Basel, Switzerland)2026
A Method for Measuring the Operating Force of Interventional Robots via Integration of Compliant Mechanisms and Sensors.
Article in Biomimetics (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Interventional robots play a crucial role in surgical procedures, where accurate force measurement is essential for enhancing safety. Compliant mechanisms utilize material deformation to achieve millinewton-scale force output and millimeter-level displacement with high repeatability. Motivated by this, we propose a method for measuring the catheter force by integrating a compliant mechanism and a sensor. First, we designed an operating force detection module. It comprises a double-parallelogram structure with four elastic units, a catheter drive module, and a sensor. The sensor connects the compliant mechanism to the base. Second, stiffness and gravity compensation models were established and validated experimentally. Finally, we constructed an experimental platform to evaluate the force measurement accuracy, drive accuracy, and real-time detection capability. Experimental results demonstrate that the proposed method achieves a maximum detection error of 0.1482 N, an average error of 0.0096 N, a resolution of 0.01 N, and an average axial delivery error of 0.8287 mm. Additionally, a master-slave control framework was developed, along with a master controller that manipulates the slave robot to deliver the catheter within a vascular phantom, while simultaneously displaying real-time force information via the human-computer interaction interface.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.