Evidence map›Paper›PMID 42041405›Full record

ArticleBiosensors2026

Patient-Friendly Real-Time Optical Tomographic Imaging System (LOTIS) for Lupus Arthritis.

Moegammad A Bardien, Lara Pinar, Alessandro Marone, Alberto Nordmann-Gomes, Leila Khalili, Stephen Suh, Stephen H Kim, Anca D Askanase, Andreas H Hielscher

Abstract read
In one paragraph

Article in Biosensors, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Moegammad A BardienDepartment of Biomedical Engineering, Tandon School of Engineering, New York University, Brooklyn, NY 11201, USA.ORCID 0000-0001-6253-5164
Lara PinarDepartment of Biomedical Engineering, Tandon School of Engineering, New York University, Brooklyn, NY 11201, USA.ORCID 0009-0002-5651-6084
Alessandro MaroneDepartment of Biomedical Engineering, Tandon School of Engineering, New York University, Brooklyn, NY 11201, USA.ORCID 0000-0003-2026-716X
Alberto Nordmann-GomesDepartment of Medicine-Rheumatology, Columbia University, Irving Medical Center, New York, NY 10032, USA.ORCID 0009-0008-9763-8209
Leila KhaliliDepartment of Medicine-Rheumatology, Columbia University, Irving Medical Center, New York, NY 10032, USA.ORCID 0000-0002-1070-0997
Stephen SuhDepartment of Medicine-Rheumatology, Columbia University, Irving Medical Center, New York, NY 10032, USA.ORCID 0009-0004-8880-6523
Stephen H KimDepartment of Biomedical Engineering, Tandon School of Engineering, New York University, Brooklyn, NY 11201, USA.ORCID 0000-0002-7687-2230
Anca D AskanaseDepartment of Medicine-Rheumatology, Columbia University, Irving Medical Center, New York, NY 10032, USA.ORCID 0000-0003-4597-5023
Andreas H HielscherDepartment of Biomedical Engineering, Tandon School of Engineering, New York University, Brooklyn, NY 11201, USA.ORCID 0000-0002-9967-056X

Funding

United States Department of Defense W81XWH-22-1-0738
6 · The paper itself

Abstract

Systemic lupus erythematosus (SLE) frequently presents joint pain and stiffness, yet clinicians lack an objective, rapid method to quantify joint inflammation at the point of care. We introduce the Lupus Optical Tomography Imaging System (LOTIS), a wearable near-infrared (NIR) device that performs real-time three-dimensional tomographic imaging of hemodynamic changes in finger joints. LOTIS was developed to address key limitations of our earlier Flexible Optical Imaging System (FOIS), including mechanical fragility, high noise levels, single-joint acquisition, and slow reconstruction times. The new system integrates modular, mechanically robust optical patches with on-sensor digitization and a computationally efficient, non-iterative multispectral reconstruction algorithm to produce frame-by-frame maps of hemoglobin concentration. In a preliminary study using a standardized venous-occlusion protocol, LOTIS differentiated SLE-affected joints from those of healthy controls. Diseased joints exhibited blunted and spatially diffuse hemodynamic responses, whereas healthy joints showed localized and robust changes. These results demonstrate that LOTIS provides an operator-independent, patient-friendly method for quantifying joint-specific hemodynamic changes in real time, offering strong potential as a clinical tool for objective assessment and longitudinal monitoring of lupus arthritis.

Indexed as

ArthritisLupus Erythematosus, SystemicTomography, OpticalHumansOptical Imaginghemodynamic monitoringjoint inflammationoptical tomographysystemic lupus erythematosuswearable device

Identifiers

PMID42041405
PMCPMC13115400

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.