Evidence map›Paper›PMID 42041231›Full record

ArticleJournal of the American Society for Mass Spectrometry2026

Absorption Mode Broadband 2D MS for Proteomics and Metabolomics.

Maria A van Agthoven, Marek Polák, Jan Fiala, Claude Nelcy Ounounou, Petr Halada, Michael Palasser, Anne Briot-Dietsch, Alan Kádek, Kathrin Breuker, Petr Novák and 2 more

Abstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Maria A van AgthovenUniversité de Rouen-Normandie, Institut CARMeN UMR 6064, IRCOF, 1 rue Tesnière, 76821 Mont St Aignan Cedex, France.ORCID 0000-0003-2438-3934
Marek PolákInstitute of Microbiology, Czech Academy of Sciences, Videnska 1083, Prague 14220, Czech Republic.ORCID 0000-0002-8929-5479
Jan FialaInstitute of Microbiology, Czech Academy of Sciences, Videnska 1083, Prague 14220, Czech Republic.
Claude Nelcy OunounouUniversité de Rouen-Normandie, Institut CARMeN UMR 6064, IRCOF, 1 rue Tesnière, 76821 Mont St Aignan Cedex, France.
Petr HaladaInstitute of Microbiology, Czech Academy of Sciences, Videnska 1083, Prague 14220, Czech Republic.
Michael PalasserCenter for Chemistry and Biomedicine, University of Innsbruck, Innrain 80/82, 6020 Innsbruck, Austria.
Anne Briot-DietschInstitut de Génétique et de Biologie Moléculaire et Cellulaire, INSERM U596, CNRS UMR 7104, Université de Strasbourg, 1 rue Laurent Fries, 67404 Illkirch, Graffenstaden, France.
Alan KádekInstitute of Microbiology, Czech Academy of Sciences, Videnska 1083, Prague 14220, Czech Republic.ORCID 0000-0002-7953-5870
Kathrin BreukerCenter for Chemistry and Biomedicine, University of Innsbruck, Innrain 80/82, 6020 Innsbruck, Austria.ORCID 0000-0002-4978-0883
Petr NovákInstitute of Microbiology, Czech Academy of Sciences, Videnska 1083, Prague 14220, Czech Republic.ORCID 0000-0001-8688-529X
Carlos AfonsoUniversité de Rouen-Normandie, Institut CARMeN UMR 6064, IRCOF, 1 rue Tesnière, 76821 Mont St Aignan Cedex, France.ORCID 0000-0002-2406-5664
Marc-André DelsucInstitut de Génétique et de Biologie Moléculaire et Cellulaire, INSERM U596, CNRS UMR 7104, Université de Strasbourg, 1 rue Laurent Fries, 67404 Illkirch, Graffenstaden, France.ORCID 0000-0002-1400-5326

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Two-dimensional mass spectrometry (2D MS) is a method for tandem mass spectrometry that enables the correlation between precursor and fragment ions without the need for ion isolation. On a Fourier transform ion cyclotron resonance mass spectrometer, the phase correction functions for absorption mode data processing were found to be linear in the precursor ion dimension and quadratic in the fragment ion dimension. Phase-corrected absorption mode data processing on limited data sets has previously shown improvements in signal-to-noise ratio (SNR) and resolving power by a factor of 2. Here, we have expanded phase-corrected absorption mode data processing to 2D mass spectra regardless of size and frequency range. We have applied phase-corrected absorption mode 2D MS to top-down analysis of variously oxidized ubiquitin proteoforms generated by fast photochemical oxidation of proteins (FPOP) and to an extract of ergot alkaloids. We show that phase-corrected absorption mode data processing significantly improves both the SNR and the resolving power of the 2D mass spectrum compared to standard magnitude mode in terms of sequence coverage in top-down proteomics, as well as the accuracy of precursor-fragment correlation in metabolomics.

Indexed as

MetabolomicsProteomicsTandem Mass SpectrometryFourier AnalysisOxidation-ReductionSignal-To-Noise RatioUbiquitinUbiquitinFT-ICR MSmetabolomicsproteomicstandem mass spectrometrytwo-dimensional mass spectrometry

Identifiers

PMID42041231
PMCPMC13235632

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.