Evidence map›Paper›PMID 42040641›Full record

ArticleJournal of arrhythmia2026

Device-Specific Responses to Pacemaker-Mediated Arrhythmia in Patients With Prolonged Ventriculoatrial Conduction: A Comparative Simulation Study.

Mitsuru Tsunomori, Teruhiko Imamura, Daisuke Nagamine, Satoshi Okino, Hitomi Iio, Kuniaki Sato, Naoya Kataoka, Keisuke Uchida, Koichiro Kinugawa

Abstract read
In one paragraph

Article in Journal of arrhythmia, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mitsuru TsunomoriMedical Equipment Management Center Toyama University Hospital Toyama Japan.ORCID https://orcid.org/0009-0003-3731-293X
Teruhiko ImamuraSecond Department of Medicine University of Toyama Toyama Japan.
Daisuke NagamineMedical Equipment Management Center Toyama University Hospital Toyama Japan.
Satoshi OkinoMedical Equipment Management Center Toyama University Hospital Toyama Japan.
Hitomi IioMedical Equipment Management Center Toyama University Hospital Toyama Japan.
Kuniaki SatoMedical Equipment Management Center Toyama University Hospital Toyama Japan.
Naoya KataokaSecond Department of Medicine University of Toyama Toyama Japan.
Keisuke UchidaSecond Department of Medicine University of Toyama Toyama Japan.
Koichiro KinugawaSecond Department of Medicine University of Toyama Toyama Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Pacemaker-mediated tachycardia (PMT) triggered by prolonged ventriculoatrial conduction (VAC) can be challenging to detect and terminate. The behavior of device-specific anti-PMT algorithms in such scenarios, as well as the potential utility of DDI mode as an alternative strategy, remain to be fully elucidated. Methods: Five dual-chamber pacemakers from Abbott, BIOTRONIK, Boston Scientific, Medtronic, and MicroPort CRM were tested using an electrophysiological simulator under VAC times of 450 ms and 550 ms. We assessed (1) PMT detection and termination in DDD mode, (2) atrial sensing within the post-ventricular atrial refractory period (PVARP) in DDI mode, and (3) the timing adjustment of atrial pacing after retrograde atrial sensing. Results: At VAC 450 ms, all devices except Medtronic detected PMT. Only Abbott terminated PMT at 550 ms with a shortened AV delay. Four devices detected atrial events within PVARP at 450 ms, whereas only BIOTRONIK did so at 550 ms. Among these, BIOTRONIK, Boston Scientific, and Medtronic adapted atrial pacing timing following atrial sensing within the refractory period, while Abbott did not, resulting in repetitive nonreentrant ventriculoatrial synchrony. Conclusions: Anti-PMT performance varies markedly among manufacturers. Devices featuring a longer PVARP and an atrial pacing delay algorithm provide superior protection against pacemaker-mediated arrhythmias during prolonged VAC. These findings underscore the importance of individualized pacemaker selection and careful programming.

Indexed as

endless loop tachycardiapacemaker‐mediated tachycardiarepetitive nonreentrant ventriculoatrial synchronyventriculoatrial conduction

Identifiers

PMID42040641
PMCPMC13106025

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.