Evidence map›Paper›PMID 42040022›Full record

ArticleGalen medical journal2024

In Vitro Evaluation of the Effect of Scanning Strategy on the Accuracy of Intraoral Scanners : In Vitro Evaluation of the Effect of Scanning Strategy on the Accuracy of Intraoral Scanners.

Mohammad Qadirifard, Mitra Eisaei, Sayed Mohammadreza Hakimaneh, Mohammad Amin Bafandeh, Sayed Shojaedin Shayegh

Abstract read
In one paragraph

Article in Galen medical journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mohammad QadirifardDepartment of Prosthodontics, Faculty of Dentistry, Shahed University, Tehran, Iran.
Mitra EisaeiDepartment of Prosthodontics, Faculty of Dentistry, Shahed University, Tehran, Iran.
Sayed Mohammadreza HakimanehDepartment of Prosthodontics, Faculty of Dentistry, Shahed University, Tehran, Iran.
Mohammad Amin BafandehDepartment of Prosthodontics, Faculty of Dentistry, Shahed University, Tehran, Iran.
Sayed Shojaedin ShayeghDepartment of Prosthodontics, Faculty of Dentistry, Shahed University, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The accuracy of intraoral scanners depends on the scanning strategy, but evidence on how these strategies affect trueness and precision across scanners is limited. Identifying optimal strategies is key to improving performance and clinical outcomes. Materials and Methods: A dental cast obtained from an impression of a fully-dentate patient was initially scanned by a laboratory scanner and then by three intraoral scanners namely Trios®4, Carestream 3800, and Medit i700 with three different scanning strategies of A (occlusal surfaces from the left end to the right end, followed by lingual and then buccal surfaces), B (buccal surfaces followed by occlusal and then lingual surfaces from left to right), and C (continuous labiolingual movement with left-to-right direction). Scans were converted to STL format and analyzed in Geomagic for trueness and precision (ISO 5725-1) using ANOVA, Tukey, Welch, and Games-Howell tests (alpha = 0.05). Results: The effect of scanning strategy was significant on trueness of Carestream (P=0.002) but not Medit and Trios4 (P0.05). In Carestream, the trueness of strategy A was significantly higher than B (P=0.001). The effect of scanning strategy was significant on precision of Medit (P0.001) but not Carestream and Trios4 (P0.05). In Medit, the precision of strategy B was significantly lower than A and C (P0.001 for both). Conclusion: The scanning strategy's effect on accuracy varied by scanner type. Strategy A was most accurate in Carestream, while strategy B showed the lowest precision in Medit i700. Other scanners and strategies had similar precision.

Indexed as

AccuracyDental ScannersPrecision

Identifiers

PMID42040022
PMCPMC12327969

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.