Evidence map›Paper›PMID 42039352›Full record

ArticleFrontiers in cardiovascular medicine2026

3D Virtual reality assessment of right ventricle-pulmonary artery conduit dilation and coronary compression risk: a retrospective bi-center feasibility study.

David Hochstein, Yona Rothé, Avshalom Shaffer, Yisrael Parmet, Oliana Vazhgovsky, Hanita Shai, Alona Raucher, Racheli Sion Sarid, Erica Pollak, Dor Freidin and 7 more

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors.

David HochsteinInternal Medicine Department C, Sheba Medical Center, Ramat Gan, Israel.
Yona RothéEngineering in Medicine Lab (EiM), Sheba Medical Center, Ramat Gan, Israel.
Avshalom ShafferEngineering in Medicine Lab (EiM), Sheba Medical Center, Ramat Gan, Israel.
Yisrael ParmetDepartment of Industrial Engineering and Management, Ben Gurion University, Beer Sheva, Israel.
Oliana VazhgovskyEngineering in Medicine Lab (EiM), Sheba Medical Center, Ramat Gan, Israel.
Hanita ShaiThe School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Alona RaucherThe School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Racheli Sion SaridThe School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Erica PollakThe School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Dor FreidinDepartment of Plastic and Reconstructive Surgery, Sheba Medical CenterRamat Gan, Israel.
Lior SassonThe School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Yishai SalemThe School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Uriel KatzThe School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Sagi AsaThe School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Netanel NagarEngineering in Medicine Lab (EiM), Sheba Medical Center, Ramat Gan, Israel.
Shai Tejman-YardenEngineering in Medicine Lab (EiM), Sheba Medical Center, Ramat Gan, Israel.
Sharon Borik ChigerThe School of Medicine, Tel Aviv University, Tel Aviv, Israel.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Right ventricle-to-pulmonary artery (RV-PA) conduits are crucial to establishing or restoring RV-PA continuity in children with complex congenital heart disease. Progressive conduit obstruction is common, particularly in growing patients, and may necessitate transcatheter dilation and stenting. One of the major procedural concerns in these cases is the risk of coronary artery compression during stent implantation. This study evaluated the technical feasibility and clinical utility of patient-specific three-dimensional (3D) reconstruction and virtual reality (VR) modeling to enhance pre-procedural planning and coronary risk assessment. Methods: This retrospective bi-center feasibility analysis of pediatric patients who underwent evaluation for RV-PA conduit dilation and stenting was conducted at the Sheba and Wolfson Medical Centers, Israel, between January 2018 and September 2022. For 19 eligible patients, cardiac CT datasets were processed to generate high-fidelity 3D VR models. Two independent cardiologists assessed the models, quantified the distances between the conduit and the major coronary arteries before and after simulated balloon expansion, and provided structured qualitative feedback on VR usability. Results: VR-based anatomical measurements demonstrated strong inter-operator agreement (intraclass correlation coefficient >0.7 across most parameters). Both cardiologists rated VR significantly superior to CT alone for delineating coronary trajectories and assessing compression risk (mean score 4.58 vs. 3.78, Conclusions: Patient-specific 3D VR modeling is technically feasible and provides clinically meaningful advantages for planning RV-PA conduit interventions. VR enhances visualization of complex coronary anatomy beyond what is achievable with standard CT imaging and may support more accurate risk stratification, improved procedural planning, and potentially reduce catheterization-associated complications. These preliminary findings support further prospective evaluation for the integration of VR tools into routine congenital cardiac practice.

Indexed as

3D reconstructioncongenital heart defect (CHD)pre-procedural planningpulmonary artery conduitvirtual reality

Identifiers

PMID42039352
PMCPMC13106117

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.