ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2026
[Study on electrospun film-covered tracheal stents with adaptive release of anti-inflammatory drugs driven by the piezoelectric effect].
Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Drug-eluting stents used to inhibit granulation tissue hyperplasia after tracheal stent implantation rely on passive drug release mechanisms, which make precise controlled release difficult and may lead to either insufficient efficacy or toxic side effects. This study aims to design a piezoelectric effect-based adaptive drug-releasing film for tracheal stents, capable of self-regulating the release of anti-inflammatory drugs according to the mechanical changes in the pathological environment within the patient's airway. First, a polyvinylidene fluoride piezoelectric film was prepared on a metal stent surface via electrospinning. Curcumin-loaded poly(3,4-ethylenedioxythiophene) conductive nanoparticles were dispersed in a polyvinyl alcohol hydrogel and adhered to the upper and lower edges of the stent (prone to hyperplasia areas). Experiments showed uniform nanoparticle morphology with a curcumin loading rate of (12.6 ± 1.80)%. Electrochemical tests indicated that the curcumin release rate was highest (approximately 90%) at a reduction potential of -1.5 V, and "on/off" controlled release could be achieved through intermittent electrical stimulation. When periodic pressure was applied to the film, its output voltage increased with loading speed (up to -8 V). Furthermore, the curcumin release rate was positively correlated with the pressure speed, reaching a cumulative release of about 15% within 48 h at a loading speed of 2.5 m/min. The drug-loaded piezoelectric film-covered stent developed in this study successfully achieves mechanically controlled release of the anti-inflammatory drug curcumin under intermittent cyclic pressure, providing an effective strategy for developing intelligent tracheal stents with adaptive and controllable drug release.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.