Evidence map›Paper›PMID 42037325›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2026

[The influence of articular surface conformity on the biomechanics of rotating hinge knee prostheses].

Ying Li, Zhifeng Zhang, Longhui Li, Jing Zhang, Zhenxian Chen, Weijie Zhang

Abstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ying LiSchool of Construction Machinery, Chang'an University, Xi'an 710064, P. R. China.
Zhifeng ZhangDepartment of Joint Surgery, the Second Affiliated Hospital of Inner Mongolia Medical University, Orthopedic Research Institute of Inner Mongolia Autonomous Region, Hohhot 010110, P. R. China.
Longhui LiSchool of Construction Machinery, Chang'an University, Xi'an 710064, P. R. China.
Jing ZhangSchool of Construction Machinery, Chang'an University, Xi'an 710064, P. R. China.
Zhenxian ChenSchool of Construction Machinery, Chang'an University, Xi'an 710064, P. R. China.
Weijie ZhangHonghui Hospital Affiliated to Xi'an Jiaotong University, Xi'an 710054, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Articular surface conformity is a critical factor influencing the biomechanics of knee prostheses, yet its impact on the biomechanics of rotation-hinged knee (RHK) prostheses and their tibial fixation remains unclear. In this study, a rotational platform tibial insert model of RHK prostheses with varying coronal and sagittal conformities is established. Finite element analysis was performed under ISO boundary conditions to investigate the effects of articular surface conformity on the biomechanics of the RHK prosthesis and tibial fixation. The study revealed that when the coronal conformity decreased from 0.83 to 0.33, the maximum Mises stress in the tibia and the maximum contact pressure in the insert increased by 10.78% and 52.62%, respectively, while the maximum shear stress in the bone cement decreased by 10.17%. When sagittal conformity decreased from 0.88 to 0.47, the maximum Mises stress in the tibia and maximum contact pressure in the insert increased by 5.62% and 14.31%, respectively, while Mises stress at the hinge-rotation axis and bone cement shear stress decreased by 62.53% and 29.46%, respectively. A reduction in conformity decreased the contact area. Sagittal conformity has a lesser impact on insert contact pressure compared to coronal conformity, but a more significant impact on bone cement shear stress, and reducing sagittal conformity could effectively reduce the Mises stress at the hinge-rotation axis. The coronal conformity of the RHK prosthesis on the rotational platform more effectively regulates contact mechanics, reducing sagittal conformity facilitates lowering hinge-rotation axis Mises stress and bone cement shear stress without significantly increasing contact pressure, thereby mitigating risks of prosthesis failure such as dislocation, fracture, and loosening.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisProsthesis DesignBiomechanical PhenomenaFinite Element AnalysisHumansKnee JointRotationStress, MechanicalSurface PropertiesTibiaBiomechanicsConformityFinite element analysisMovable tibial insertRotating hinge knee prosthesis

Identifiers

PMID42037325
PMCPMC13112226

What OpenQuestion holds