Evidence map›Paper›PMID 42035479›Full record

ArticleClinical and experimental dental research2026

Flexural Strength, Monomer Release, and Wear of Occlusal Splint Materials Fabricated Through Conventional, Milled, or 3D-Printed Methods.

Nurul Liyana Aminuddin, Haralampos Petridis

Abstract read
In one paragraph

Article in Clinical and experimental dental research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Nurul Liyana AminuddinDepartment of Prosthodontics, UCL Eastman Dental Institute, London, England, UK.ORCID 0009-0006-7868-1864
Haralampos PetridisDepartment of Prosthodontics, UCL Eastman Dental Institute, London, England, UK.ORCID 0000-0003-4593-1127

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo evaluate the flexural strength, monomer release, and wear resistance between conventional, milled polymethylmethacrylate (PMMA), and 3D-printed resins built at 90° and 60° printing angles for occlusal splints. MATERIALS AND

methods60-rectangular and 100-disc specimens were fabricated from heat-cured PMMA (Oracryl [HP], Bracon Dental, United Kingdom), milled PMMA (Kerox Premia [KP], Kerox Dental, Hungary), and 3D-printed resins (FreePrint Splint2.0 [FS], Detax, Ettlingen, Germany, and KeySplint Hard [KS], Keystone Industries, Myerstown, USA) at 90° and 60° printing angles. Specimens for flexural strength and wear tests were immersed immediately in 37°C water for 50 h and thermally aged for 20,000 cycles. Flexural strength was evaluated using a three-point bend test. Wear was tested using a chewing simulator for 140,000 cycles, and volume loss was calculated using Autodesk MeshMixer software. Monomer release was analyzed via UV spectrophotometry over 7 days. Statistical analysis was performed using the Shapiro-Wilk test and one-way ANOVA with Tukey's multiple comparison tests.

resultsKP showed the highest mean flexural strength (115.5 ± 5.3 MPa, p < 0.0001), followed by HP (86.6 ± 10.8 MPa, p < 0.0001), with 3D-printed resin showed the lowest. Meanwhile 90° FS showed greater flexural strength (60.5 ± 3.8 MPa) compared to 60° FS (p < 0.001) and KS (p < 0.01). The difference between 90° and 60° KS were not statistically significant (p > 0.05). Monomer release peaked on Day 3 for all groups, with KS consistently showing the highest concentration (29.7 ± 3.6 ppm), followed by FS (28.8 ± 3.8 ppm), HP (27.9 ± 4.9 ppm), and lastly, KP showed the lowest concentration (24.9 ± 3.8 ppm). KP demonstrated the lowest mean volume loss (2.5 ± 1.3 mm

conclusionMilled PMMA outperformed other materials, followed by conventional PMMA, while 3D-printed resin showed inferior performance in flexural strength, wear resistance, and monomer release. Printing angles significantly influenced flexural strength but not wear properties in 3D-printed resins.

Indexed as

Dental MaterialsDental Restoration WearOcclusal SplintsPolymethyl MethacrylatePrinting, Three-DimensionalAcrylic ResinsDental Stress AnalysisFlexural StrengthHumansMaterials TestingAcrylic ResinsDental MaterialsPolymethyl Methacrylateflexural strengthmonomer releaseocclusal splintwear resistance

Identifiers

PMID42035479
PMCPMC13110832

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.