Evidence map›Paper›PMID 42035179›Full record

ArticleJournal of cardiothoracic surgery2026

Mid-term outcomes and hemodynamic performance of Edwards 19-mm-labeled aortic valve bioprostheses: a single-center retrospective study.

Takayuki Gyoten, Takayuki Akatsu, Taro Kuroda, Yu Kumagai, Yuko Gatate, Akihiro Yoshitake

Abstract read
In one paragraph

Article in Journal of cardiothoracic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Takayuki GyotenDepartment of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-1298, Saitama, Japan. t.gyoten29@gmail.com.
Takayuki AkatsuDepartment of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-1298, Saitama, Japan.
Taro KurodaDepartment of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-1298, Saitama, Japan.
Yu KumagaiDepartment of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-1298, Saitama, Japan.
Yuko GatateDepartment of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-1298, Saitama, Japan.
Akihiro YoshitakeDepartment of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-1298, Saitama, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aimed to evaluate clinical outcomes after surgical aortic valve replacement with third-generation Edwards (Edwards Lifesciences, Irvine, CA, USA) 19-mm-labeled aortic valve bioprostheses, including a rapid-deployment sutureless valve (Intuity valve) for small aortic annuli at a high-volume Japanese heart center.

methodsWe retrospectively analyzed the outcomes of adult patients with symptomatic aortic valve stenosis, regurgitation, or valve deterioration who underwent 19-mm-labeled aortic valve bioprostheses replacement (Edwards products: Inspiris, Magna, and Intuity) for small aortic annuli at our center between January 2015 and August 2024. The primary and secondary endpoints were all-cause mortality after implantation and major adverse cardiac and cardiovascular events (MACCE), respectively. We also analyzed the hemodynamic performances of the different aortic bioprostheses.

resultsOverall, 137 patients (median age, 76 years [interquartile range (IQR): 72 - 80]; 122 females [89%]) underwent surgical aortic valve replacement with 19-mm Edwards aortic valve bioprostheses (Inspiris, n = 58; Magna, n = 69; Intuity, n = 10). The median follow-up duration was 71 months (IQR: 34 - 103). Overall survival rates at 1, 3, and 5 years after valve replacement were 91.9%, 86.5%, and 84.8% (95% confidence interval [CI]: 85.9 - 95.5; 79.4 - 91.3; 77.4 - 89.9), respectively. Freedom from MACCE at 1, 3, and 5 years was 94.8%, 89.8%, and 88.8% (95%CI: 89.4 - 97.5; 83.0 - 93.9; 81.7 - 93.2), respectively. Among the three types of valves, the survival and rate of freedom from MACCE did not differ significantly (p = 0.29 and p = 0.48, respectively). Furthermore, no significant differences in hemodynamics were observed among the different aortic bioprostheses.

conclusionSurgical replacement using 19-mm-labeled Edwards aortic valve bioprostheses for small aortic annuli is a feasible therapeutic option in this population, demonstrating favorable early- and mid-term hemodynamic parameters.

Indexed as

Aortic ValveAortic Valve StenosisBioprosthesisHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHemodynamicsAgedAged, 80 and overFemaleFollow-Up StudiesHumansMaleProsthesis DesignRetrospective StudiesTreatment OutcomeAortic valve replacementBioprosthesesSmall aortic annulus

Identifiers

PMID42035179
PMCPMC13262422

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.