ArticleJournal of feline medicine and surgery2026
Accuracy of intraoperative CT to determine implant position in the feline vertebral spine.
Article in Journal of feline medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
ObjectivesThe aim of this study was to evaluate the accuracy of cone-beam CT (CBCT) for predicting implant position relative to the vertebral canal in the feline thoracolumbar vertebral column.MethodsThis in vitro imaging and anatomical study included 22 feline cadavers. A realistic surgical approach was performed at three thoracolumbar locations. Four smooth 1.2 mm Kirschner wires were inserted per location using the recommended insertion points. Perforation of the spinal canal was not avoided. Images from end-on fluoroscopy (eoF), multi-slice CT (MSCT) and CBCT using a C-arm were obtained. The images were randomised, and the implant position was assessed by four evaluators who classified implant position and recorded their subjective certainty. Sensitivity, specificity and accuracy were calculated using anatomical dissection as the reference standard. Interrater agreement was assessed using Fleiss' kappa (κ). Duration of image acquisition was compared across modalities using a mixed-effects linear model.ResultsFor eoF, the sensitivity and specificity were 81.9% and 80.7%, respectively, with a balanced accuracy of 81.3% (95% confidence interval [CI] 0.79-0.84) and good κ agreement (0.63). For MSCT, sensitivity was 80.2% and specificity was 83.1%. Balanced accuracy was 81.7% (95% CI 0.79-0.84) and κ was good (0.63). CBCT showed a sensitivity of 88.5% and specificity of 83.4%, with a balanced accuracy of 85.9% (95% CI 0.84-0.88) and good κ agreement (0.72). Interrater reliability showed overall κ values of 0.38 for eoF, 0.54 for MSCT and 0.58 for CBCT. Interrater reliability was higher for completely perforating and non-perforating implants and lower for partially perforating implants. CBCT and eoF were performed faster than MSCT (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.