Irreversible electroporation ablation with bipolar electrodes: ultrasound findings of ablation zones.

Linyu Zhou, Qiang Chen, Ju Li, Chengyue Zhang, Shengyong Yin, Min Xu, Tian'an Jiang

Abstract read
In one paragraph

Article in Radiology and oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Linyu Zhou1Department of Ultrasound, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
Qiang Chen2Zhejiang Curaway Medical Technology Co., Ltd, Hangzhou, China.
Ju Li1Department of Ultrasound, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
Chengyue Zhang1Department of Ultrasound, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
Shengyong Yin3The First Affiliated Hospital, Key Laboratory of Combined Multi-Organ Transplantation, Ministry of Public Health, Zhejiang University School of Medicine, Hangzhou, China.
Min Xu1Department of Ultrasound, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
Tian'an Jiang1Department of Ultrasound, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aimed to explore the ultrasound and contrast-enhanced ultrasound (CEUS) imaging characteristics and dimensions of ablation lesions after irreversible electroporation of the swine liver and to determine which imaging modality is more suitable for post-procedural follow-up by correlating imaging findings with histopathology. MATERIALS AND

methodsIrreversible electroporation procedures were conducted on three swine with single bipolar electrodes. All procedures were carried out after laparotomy. Twenty-four ablation zones were created under ultrasound guidance. Ultrasound and CEUS evaluations were performed immediately and 48 h after irreversible electroporation. Liver specimens were harvested 48 h after irreversible electroporation for histopathological analysis.

resultsThe ablation area appeared as a hypoechoic, well-defined lesion on ultrasound and showed no enhancement on CEUS immediately after irreversible electroporation. At 48 h, the ablation zone appeared as an inhomogeneous hyperechoic area with a hyperechoic margin and blurred boundaries on ultrasound. CEUS clearly delineated the boundary of the ablation zone and demonstrated centripetal enhancement. The dimensions of the ablation area measured on CEUS 48 h after irreversible electroporation showed the highest correlation with the pathologic ablation zone size (length: r = 0.909, width: r = 0.942, p < 0.001), whereas ultrasound measurements showed the lowest correlation (length: r = 0.676, width: r = 0.842, p < 0.001).

conclusionsCompared with conventional ultrasound, CEUS can accurately measure the dimension of the ablation area, especially 48 h after irreversible electroporation.

Indexed as

ElectroporationIrreversible Electroporation TherapyLiverAnimalsContrast MediaElectrodesSwineUltrasonographyContrast Mediaanimal experimentscontrast-enhanced ultrasoundirreversible electroporationliverultrasound

Identifiers

PMID42030077
PMCPMC13307009

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.