Evidence map›Paper›PMID 42028052›Full record

ArticleBiophotonics discovery2026

Advancing subclinical keratoconus detection using polarization-sensitive optical coherence tomography and artificial intelligence.

Rahul P Patil, Raghav Narasimhan, Anchana Pisharody, Rohit Shetty, Pooja Khamar, Vinodhini Devendiran, Rudy M M A Nuijts, Abhijit Sinha Roy

Abstract read
In one paragraph

Article in Biophotonics discovery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Rahul P PatilNarayana Nethralaya Foundation, Imaging, Biomechanics and Mathematical Modelling Solutions Laboratory, Bangalore, Karnataka, India.ORCID https://orcid.org/0009-0007-3176-7107
Raghav NarasimhanNarayana Nethralaya Foundation, Imaging, Biomechanics and Mathematical Modelling Solutions Laboratory, Bangalore, Karnataka, India.
Anchana PisharodyNarayana Nethralaya Foundation, Imaging, Biomechanics and Mathematical Modelling Solutions Laboratory, Bangalore, Karnataka, India.
Rohit ShettyNarayana Nethralaya Eye Hospital, Department of Cornea and Refractive Surgery, Bangalore, Karnataka, India.
Pooja KhamarNarayana Nethralaya Eye Hospital, Department of Cornea and Refractive Surgery, Bangalore, Karnataka, India.
Vinodhini DevendiranNarayana Nethralaya Foundation, Imaging, Biomechanics and Mathematical Modelling Solutions Laboratory, Bangalore, Karnataka, India.
Rudy M M A NuijtsMaastricht University Medical Center, Department of Ophthalmology, Maastricht, The Netherlands.
Abhijit Sinha RoyNarayana Nethralaya Foundation, Imaging, Biomechanics and Mathematical Modelling Solutions Laboratory, Bangalore, Karnataka, India.ORCID https://orcid.org/0000-0003-2039-728X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Significance: Early detection of keratoconus (KC), a progressive corneal disorder, remains a major clinical challenge. Polarization-sensitive optical coherence tomography (PS-OCT) is an advanced imaging technique that can quantify corneal birefringence, offering insight into collagen organization and microstructural integrity. Approach: A total of 359 eyes were examined and evaluated. This study explores PS-OCT-derived phase retardation (PR) and corneal sublayer thickness as potential diagnostic biomarkers for healthy, subclinical (SKC), and KC eyes. Further, the performance of AI-based classification models developed from PS-OCT, Pentacam, and MS-39 data were compared, using random forest classifier trained with a leave-one-out methodology and identical hyperparameter settings. Results: All AI models demonstrated comparable accuracy among devices for healthy and KC detection. However, SKC classification differed from Pentacam and MS-39. Here, 39.5% of the SKC eyes were reclassified as healthy by PS-OCT, compared with 27.5% by Pentacam and 30.3% by MS-39. The average diagnostic performance of PS-OCT included an AUC, precision, recall, F1 score, and accuracy of 0.91, 83%, 82%, 0.82, and 82%, respectively. For the Pentacam, the same were 0.95, 87%, 86%, 0.86, and 86%, respectively. For the MS-39, the same were 0.94, 86%, 86%, 0.85, and 86%, respectively. Conclusions: Overall, AI model agreement was strong for healthy and KC groups but varied in SKC. PS-OCT provides complementary diagnostic value and may refine subclinical KC detection for safer refractive surgery decisions.

Indexed as

artificial-intelligenceclassification.corneakeratoconuspolarization-sensitiveps-oct

Identifiers

PMID42028052
PMCPMC13052500

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.