ArticleHardwareX2026
ESPiezometer: ESP32-based field tool for installation and validation of piezometric sensors for groundwater level monitoring.
Article in HardwareX, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Field installation of piezometric sensors often involves uncertainty regarding correct placement, sensor response, and agreement with manually measured static water levels. Commercial dataloggers provide high-resolution monitoring but do not offer installation-stage validation or open access to communication protocols. To address this gap, the ESPiezometer was developed as a low-cost, open-source device based on an ESP32-C3 microcontroller with RS485 Modbus communication, on-board water level calculation, temperature-based density correction, and Bluetooth Low Energy (BLE) integration for field data logging via an Android application. The hardware enables real-time verification of raw and corrected water level readings during deployment and allows immediate comparison with manual measurements. A custom PCB and 3D-printed enclosure were designed to facilitate reproducible assembly and portability. Field validation in a groundwater observation well (30-90 m depth range) demonstrated consistent communication integrity via CRC checks and measurement repeatability with a standard deviation below 0.03 m. After density correction, measurement error was reduced by 35-50% relative to manual reference levels. The obtained results demonstrate that the ESPiezometer can serve as a reliable companion instrument, reducing uncertainty during deployment and improving confidence in long-term groundwater monitoring campaigns.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.