Evidence map›Paper›PMID 42026660›Full record

ArticleJournal of radiation research2026

Feasibility of nonspinal bony landmark-based image registration in CyberKnife ® robotic radiotherapy for pelvic and femoral bone tumors.

Yasuhide Miyabe, Hiromu Yamanaka, Hiroto Seki, Yusuke Muroi, Shinri Nakano, Ryota Yamazaki, Azusa Awaya, Jyunetsu Mizoe

Abstract read
In one paragraph

Article in Journal of radiation research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yasuhide MiyabeSapporo High Functioning Radiotherapy Center, Sapporo Kojinkai Memorial Hospital, 1-16-1 Miyanosawa 2-jo, Nishi-ku, Sapporo-shi, Hokkaido 063-0052, Japan.ORCID 0009-0000-3308-8748
Hiromu YamanakaSapporo High Functioning Radiotherapy Center, Sapporo Kojinkai Memorial Hospital, 1-16-1 Miyanosawa 2-jo, Nishi-ku, Sapporo-shi, Hokkaido 063-0052, Japan.
Hiroto SekiSapporo High Functioning Radiotherapy Center, Sapporo Kojinkai Memorial Hospital, 1-16-1 Miyanosawa 2-jo, Nishi-ku, Sapporo-shi, Hokkaido 063-0052, Japan.
Yusuke MuroiSapporo High Functioning Radiotherapy Center, Sapporo Kojinkai Memorial Hospital, 1-16-1 Miyanosawa 2-jo, Nishi-ku, Sapporo-shi, Hokkaido 063-0052, Japan.
Shinri NakanoSapporo High Functioning Radiotherapy Center, Sapporo Kojinkai Memorial Hospital, 1-16-1 Miyanosawa 2-jo, Nishi-ku, Sapporo-shi, Hokkaido 063-0052, Japan.
Ryota YamazakiSapporo High Functioning Radiotherapy Center, Sapporo Kojinkai Memorial Hospital, 1-16-1 Miyanosawa 2-jo, Nishi-ku, Sapporo-shi, Hokkaido 063-0052, Japan.
Azusa AwayaSapporo High Functioning Radiotherapy Center, Sapporo Kojinkai Memorial Hospital, 1-16-1 Miyanosawa 2-jo, Nishi-ku, Sapporo-shi, Hokkaido 063-0052, Japan.
Jyunetsu MizoeSapporo High Functioning Radiotherapy Center, Sapporo Kojinkai Memorial Hospital, 1-16-1 Miyanosawa 2-jo, Nishi-ku, Sapporo-shi, Hokkaido 063-0052, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In stereotactic body radiotherapy for bone metastases using the CyberKnife system, spinal anatomy is generally employed as the alignment reference. However, when treating pelvic tumors such as those in the pubic bone or proximal femur, the spinal reference may be anatomically distant from the target, potentially compromising visualization and localization accuracy. This study evaluated the feasibility of using nonspinal bony landmarks, specifically the pubic bone and femoral neck, as reference points for image registration. Intrafractional positional deviations in six degrees of freedom and the frequency of intrafractional corrections were analyzed according to treatment site, including cases treated with conventional spine-based alignment. Alignment accuracy was visually and numerically verified by the treatment operator before beam delivery. Across all treatment sites, the mean translational and rotational deviations during treatment remained within ±0.5 mm and ± 0.5°, respectively. Furthermore, no substantial differences were observed in the mean frequency of intrafractional corrections among the different alignment approaches. These findings demonstrate that nonspinal tumor-adjacent bony landmarks can provide clinically acceptable accuracy comparable to conventional spine-based registration. To our knowledge, this is the first study to systematically assess the clinical feasibility of this approach in CyberKnife-based pelvic radiotherapy. The proposed method may serve as a practical and reliable alternative to spine-based alignment, particularly when the spine is remote from the target.

Indexed as

Anatomic LandmarksFemoral NeoplasmsPelvic BonesPelvic NeoplasmsRadiosurgeryRadiotherapy, Image-GuidedRobotic Surgical ProceduresFeasibility StudiesFemaleHumansReproducibility of ResultsSensitivity and SpecificityTomography, X-Ray Computedbone metastasesCyberKnifeimage registrationstereotactic radiotherapy

Identifiers

PMID42026660
PMCPMC13202333

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.