Evidence map›Paper›PMID 42026612›Full record

ArticleBMC oral health2026

Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis.

Abdulaziz Gul, Emil Bureau, Jonas P Becktor, Per Vult von Steyern, Evaggelia Papia

Abstract read
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Abdulaziz GulDepartment of Materials Science and Technology, Division 2, Faculty of Odontology, Malmö University, Malmö, SE-205 06, Sweden. abdulaziz.gul@mau.se.ORCID 0000-0001-7726-7086
Emil Bureau *Det Tekniske Bureau, Copenhagen, Danmark.
Jonas P Becktor *Department of Oral and Maxillofacial Surgery and Oral Medicine, Division 2, Faculty of Odontology, Malmö University, Malmö, SE-205 06, Sweden.ORCID 0000-0002-4132-9692
Per Vult von Steyern *Department of Materials Science and Technology, Division 2, Faculty of Odontology, Malmö University, Malmö, SE-205 06, Sweden.ORCID 0009-0002-9324-7186
Evaggelia Papia *Department of Materials Science and Technology, Division 2, Faculty of Odontology, Malmö University, Malmö, SE-205 06, Sweden.ORCID 0000-0001-6260-473X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundVarious designs of dental implants made of zirconium dioxide (zirconia) as an alternative to titanium implants are available as one-piece implant (OPI) or as bone-level or tissue-level two-piece implants (TPI) with either ceramic or titanium abutment screw types of implant-abutment connections. This study aimed to identify and quantify stress concentrations and levels across different zirconia implant designs under a quasi-static external load.

methodsThe study used a finite element analysis (FEA) simulation model, including five zirconia implant design models of OPI and bone-level and tissue-level TPI zirconia implants with either ceramic or titanium abutment screw, to calculate and locate maximum principal (σ1) and minimum principal (σ3) and equivalent (von Mises) stresses under 400N of quasi-static loading at a 30-degree angle within ISO14801:2016 geometry and boundary conditions. The FEA assumed linear elastic and isotropic material properties.

resultsOPI showed high stress concentrations at the implant body’s external thread above the specimen holder. TPIs showed similar maximum principal stress (σ1) areas in their implant body, while minimum principal stress (σ3) occurred in the implant–abutment interface at the abutment neck, and the corresponding area in the implant platform. The TPIs with ceramic screws exhibited the highest stresses at the screw–abutment interface.

conclusionsWithin the limitations of this study, under a static oblique load applied within the ISO 14801:2016 geometry condition, stress distributions differ between OPI and TPI. TPIs show lower stress within the implant body but higher stress transfer to the specimen holder compared with OPI. Tissue-level TPIs exhibit lower stress than bone-level designs, whereas stresses in the abutment and screw depend on screw design and material. TPIs with ceramic screws exhibit higher stress levels compared to titanium screw.

Indexed as

CeramicsDental AbutmentsDental Implant-Abutment DesignDental ImplantsDental Stress AnalysisTitaniumZirconiumBone ScrewsDental MaterialsFinite Element AnalysisHumansMaterials TestingStress, MechanicalDental ImplantsDental MaterialsTitaniumZirconiumzirconium oxideBone-levelCeramicsDental implantsFinite element analysisImplant designOne-piece implantScrew materialStress analysisTissue-levelZirconia

Identifiers

PMID42026612
PMCPMC13135704

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.