Evidence map›Paper›PMID 42026427›Full record

ArticleJournal of applied clinical medical physics2026

Clinical implementation and evaluation of a patient-specific surface-guided clearance mapping system for collision avoidance and noncoplanar beam planning.

Siqiu Wang, Eric Chambers, Ruiqi Li, Yesenia Gonzalez, Xinran Zhong, Zohaib Iqbal, Kara James, Jennifer Cleaton, David Sher, Andrew Godley and 1 more

Abstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Siqiu WangDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.ORCID https://orcid.org/0000-0002-7360-7212
Eric ChambersDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
Ruiqi LiDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.ORCID https://orcid.org/0000-0003-4123-3807
Yesenia GonzalezDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
Xinran ZhongDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.ORCID https://orcid.org/0000-0002-2530-5228
Zohaib IqbalDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
Kara JamesDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
Jennifer CleatonDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
David SherDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
Andrew GodleyDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
David ParsonsDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.ORCID https://orcid.org/0000-0002-4466-0647

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

PURPOSE/

objectivesCollision avoidance is critical in external beam radiotherapy to ensure patient safety and plan deliverability. Limited understanding of the collision-free treatment space risks both patient safety and unnecessary exclusion of useful beams-particularly in noncoplanar setups-resulting in suboptimal plans. Conventional methods (manual clearance checks or CT-based assessments, etc.) are either labor-intensive or fail to account for collision-prone anatomy outside the scan. We investigated and clinically implemented a virtual patient-specific clearance mapping system and evaluated its utility as a noncoplanar beam selection tool to improve plan quality. MATERIALS/

methodsThe system integrates full-body, patient-specific surfaces-acquired during simulation using near-infrared imaging-with interactive 3D linac/couch models. Clearance mapping accuracy was validated through phantom measurements and a comparative analysis with manual clearance checks of 60 patients across treatment sites. Workflow efficiency data were reported over three years of clinical implementation. A workflow for patient-specific non coplanar beam selection was proposed and evaluated in 20 lung stereotactic body radiation therapy (SBRT) and 18 breast stereotactic partial breast irradiation (sPBI) cases.

resultsThe clearance mapping accuracy was within ± 1° (gantry/couch rotation) of phantom measurements. For 60 patients, the virtual predictions accurately identified all potential clearance issues, while manual verification missed 5 collision events. Virtual checks saved approximately 15 min of linac and therapist time per plan and eliminated an average 6.2-clinical hour planning delay. With the proposed beam selection workflow, noncoplanar replans for lung SBRT improved target conformality (Paddick Conformity Index from 0.89 to 0.91, p < 0.01) and reduced low dose spillage. For breast sPBI, heart mean dose was lowered (103 cGy to 68 cGy, p < 0.01). Delivery time increased by approx. 30s per plan.

conclusionsThe virtual clearance mapping system outperformed manual verification, streamlined clinical workflow, and could significantly improve plan quality through efficient noncoplanar beam selection. It has replaced manual verification at our institution.

Indexed as

Breast NeoplasmsLung NeoplasmsPhantoms, ImagingRadiosurgeryRadiotherapy Planning, Computer-AssistedFemaleHumansImage Processing, Computer-AssistedOrgans at RiskParticle AcceleratorsRadiotherapy DosageRadiotherapy, Intensity-ModulatedTomography, X-Ray Computedclearance mappingnoncoplanar treatmentpatient safetysurface‐guided radiotherapy

Identifiers

PMID42026427
PMCPMC13106023

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.