Evidence map›Paper›PMID 42026211›Full record

ArticlePediatric research2026

Utility of electrical impedance tomography to measure neonatal pulmonary circulation changes: a lamb study.

Sienna L Koeppenkastrop, Prue M Pereira-Fantini, Nicholas F Schinckel, Isabella Stafford, Georgie M Dowse, Michael Mh Cheung, David G Tingay

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sienna L KoeppenkastropNeonatal Research, Murdoch Children's Research Institute, Parkville, Australia. sienna.koeppenkastro@mcri.edu.au.ORCID http://orcid.org/0009-0003-9811-1138
Prue M Pereira-FantiniNeonatal Research, Murdoch Children's Research Institute, Parkville, Australia.
Nicholas F SchinckelNeonatal Research, Murdoch Children's Research Institute, Parkville, Australia.
Isabella StaffordNeonatal Research, Murdoch Children's Research Institute, Parkville, Australia.
Georgie M DowseNeonatal Research, Murdoch Children's Research Institute, Parkville, Australia.
Michael Mh CheungCardiology, The Royal Children's Hospital, Parkville, Australia.
David G TingayNeonatal Research, Murdoch Children's Research Institute, Parkville, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundElectrical impedance tomography (EIT) has been proposed as a bedside method of measuring pulmonary blood patterns in neonates. However, EIT's use has been limited by technical issues including cardiac-motion artefact and ventilation masking the heartbeat-related signals (HRS). This study aims to determine EIT-derived pulmonary blood volume patterns in two distinct biological models.

methodsThe HRS were extracted from EIT recordings during Study A: 10 ml saline administered into the right atrium of apnoeic lambs (n = 6) with cardiac output, and during asystole. Study B: A sustained inflation (aeration without tidal ventilation) during the respiratory transition at birth in preterm lambs (n = 12).

resultsStudy A: There was a significant fall in HRS-impedance within lung regions upon administration of saline that was independent of cardiac output (p < 0.0001, Two-way repeated-measure ANOVA), which was not influenced by cardiac motion (p = 0.16), suggesting EIT can detect changes to pulmonary arterial bed blood volume. Study B: The amplitude of the HRS decreased linearly during aeration (R

conclusionEIT demonstrated expected pulmonary blood volume changes in the lung independent of cardiac motion, highlighting EIT's potential to measure ventilation and pulmonary circulation mismatch in neonates. IMPACT: EIT may represent a future potential solution to the lack of non-invasive and radiation-free measurements of ventilation and pulmonary perfusion in neonates. Our study showed that EIT can detect changes in thoracic impedance that are independent of ventilation and heart motion within the chest and can delineate pulmonary vascular changes that occur at birth. This suggests EIT could be used to detect blood volume changes in the lungs of neonates in the immediate postnatal period.

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked