Evidence map›Paper›PMID 42024289›Full record

ArticleJournal of medical systems2026

Signal Detection Using Change Point Analysis to Identify Safety Signals from Spontaneous Reports in Aortic Stent Grafts in Japan.

Kohei Takahashi, Hideto Yokoi, Fumiaki Mikami, Tomomi Satomi, Morikazu Seki, Takako Takayama Niwa, Hideki Hanaoka, Yosuke Inaba, Daisuke Koide

Abstract read
In one paragraph

Article in Journal of medical systems, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Kohei TakahashiBiostatistics section, Clinical Research Center, Chiba University Hospital, Chiba, Japan. kohei.high84@chiba-u.jp.ORCID http://orcid.org/0009-0009-3528-5695
Hideto YokoiDepartment of Medical Informatics, Kagawa University Hospital, Kagawa, Japan.
Fumiaki MikamiDepartment of Medical Informatics, Kagawa University Hospital, Kagawa, Japan.
Tomomi SatomiDivision of Medical Safety and Report Management Office of Vigilance and Standards for Medical Devices, Pharmaceuticals and Medical Devices Agency, Tokyo, Japan.
Morikazu SekiDivision of Medical Safety and Report Management Office of Vigilance and Standards for Medical Devices, Pharmaceuticals and Medical Devices Agency, Tokyo, Japan.
Takako Takayama NiwaDivision of Medical Safety and Report Management Office of Vigilance and Standards for Medical Devices, Pharmaceuticals and Medical Devices Agency, Tokyo, Japan.
Hideki HanaokaClinical Research Center, Chiba University Hospital, Chiba, Japan.
Yosuke InabaBiostatistics section, Clinical Research Center, Chiba University Hospital, Chiba, Japan.ORCID http://orcid.org/0000-0002-8659-2873
Daisuke KoideDepartment of Biostatistics and Bioinformatics, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.ORCID http://orcid.org/0000-0002-4238-0334

Funding

Japan Agency for Medical Research and Development 23mk0101234h0002Japan Agency for Medical Research and Development JP21lk0201701
6 · The paper itself

Abstract

Signal detection is essential for identifying potential safety issues with drugs and medical devices. Change point analysis (CPA) detects changes in longitudinal data for a medical device without incorporating comparisons with other devices. This study investigated the temporal relationship between endoleak reports for aortic stent grafts identified using CPA and the issuance of the "Pharmaceuticals and Medical Devices Agency (PMDA) Alert for Proper Use of Medical Devices" in Japan. Device malfunction and adverse event reports for aortic stent grafts submitted to the PMDA between April 2008 and September 2022 were analyzed. The reports were mapped to the Medical Device Problem Terminology from the Japan Federation of Medical Devices Associations. CPA was used to identify temporal changes in report counts, with change points having confidence levels ≥ 90% being considered significant. A total of 20,678 reports were analyzed, including 23,541 device malfunctions and 30,500 adverse events. Endoleaks accounted for 10,779 events. CPA identified a significant increase in endoleak events in April 2015 (2 years before the regulatory alert). Confidence levels exceeded 90% in 76 out of 174 evaluated time points, first in July 2008 (9 years before the alert) and next in April 2016 (1 year before the alert). Based on these findings, CPA may help prioritize investigations of medical-device-related malfunctions and adverse events. However, the results do not indicate earlier or superior signal detection relative to regulatory authorities. Further research is needed to assess CPA's applicability to other medical devices and malfunctions.

Indexed as

EndoleakStentsEquipment FailureHumansJapanChange point analysisDevice malfunctionMedical deviceSignal detectionSpontaneous report

Identifiers

PMID42024289
PMCPMC13106239

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked