ArticleCatheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions2026

Single Centre Experience With the Balloon-Expandable Myval Transcatheter Aortic Valve System in Patients With Bicuspid Anatomy: 1 Year Follow-Up.

Balázs Magyari, Bálint Kittka, Ilona Goják, Gábor Kasza, Kristóf Schönfeld, László Botond Szapáry, Mihály Simon, Rudolf Kiss, Andrea Bertalan, Edit Várady and 2 more

Abstract read
In one paragraph

Article in Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Balázs MagyariHeart Institute, Medical School, University of Pécs, Pécs, Hungary.
Bálint KittkaHeart Institute, Medical School, University of Pécs, Pécs, Hungary.
Ilona GojákHeart Institute, Medical School, University of Pécs, Pécs, Hungary.
Gábor KaszaDepartment of Vascular Surgery, Medical School, University of Pécs, Pécs, Hungary.
Kristóf SchönfeldHeart Institute, Medical School, University of Pécs, Pécs, Hungary.
László Botond SzapáryHeart Institute, Medical School, University of Pécs, Pécs, Hungary.
Mihály SimonHeart Institute, Medical School, University of Pécs, Pécs, Hungary.
Rudolf KissHeart Institute, Medical School, University of Pécs, Pécs, Hungary.
Andrea BertalanHeart Institute, Medical School, University of Pécs, Pécs, Hungary.
Edit VáradyDepartment of Medical Imaging, Medical School, University of Pécs, Pécs, Hungary.
István SzokodiHeart Institute, Medical School, University of Pécs, Pécs, Hungary.
Iván HorváthHeart Institute, Medical School, University of Pécs, Pécs, Hungary.

Funding

National Research, Development, and Innovation Office of Hungary NKFIH K120536
6 · The paper itself

Abstract

backgroundTranscatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) anatomy remains challenging due to anatomical complexity and limited trial data. New-generation balloon-expandable valves, such as Myval, require further evaluation in this subgroup.

aimsTo report 1-year VARC-3 outcomes following TAVI procedure with the Myval transcatheter heart valve (THV) in BAV anatomy.

methodsFrom December 2019 to July 2023, 52 consecutive BAV patients at moderate-to-high surgical risk or deemed unsuitable for surgery underwent TAVI with the Myval THV. Outcomes, assessed per VARC-3 definitions, were compared to 217 trileaflet aortic valve (TAV) patients in unmatched and propensity score-matched cohorts.

resultsAt 1 year, BAV and TAV patients showed no significant differences in all-cause mortality (3.9% vs. 10.2%, p = 0.185), cardiac mortality (0% vs. 2.3%, p = 0.587), or stroke (3.9% vs. 2.8%, p = 0.654) regarding an unmatched comparison. In the matched analysis, all-cause mortality and stroke were 3.9% and 1.9%, respectively, with no cardiac deaths. Endocarditis was rare (1.9% vs. 1.4%, p = 0.579); no valve thrombosis occurred. At 1 year, 94% of matched patients were in NYHA class I. Echocardiographic parameters remained stable; no moderate/severe paravalvular regurgitation was observed in BAV patients. Kaplan-Meier analysis revealed no differences in survival or composite outcomes. Technical and device success rates exceeded 95%; early safety was limited by a high incidence of non-vascular type 2-4 bleeding events. Based on the analyses, the relatively high postprocedural PPI rate (unmatched BAV vs. TAV: 34.0% vs. 30.4%, p = 0.429; matched: 34.0% vs. 24.0%, p = 0.274) is more likely attributable to patient-related characteristics rather than device-related complications, and remained unchanged following hospital discharge.

conclusionsTAVI with the Myval THV in real-world BAV patients is safe and effective with excellent hemodynamic performance at 1 year follow-up. This may reinforce the use of this device in this anatomically complex population.

Indexed as

Aortic ValveAortic Valve StenosisBalloon ValvuloplastyBicuspid Aortic Valve DiseaseHeart Valve ProsthesisTranscatheter Aortic Valve ReplacementAgedAged, 80 and overFemaleFollow-Up StudiesHumansMaleProsthesis DesignRecovery of FunctionRetrospective StudiesRisk Assessmentannular ruptureballoon expendable transcatheter heart valvebicuspid aortic valveparavalvular leakpermanent pacemaker implantationTAVR