Evidence map›Paper›PMID 42020683›Full record

ArticleScientific reports2026

Toward XRF-like chemical sensitivity in the laboratory: first hyperspectral x-ray imaging demonstration using the novel CITIUS detector.

V Di Trapani, P Thibault, F Arfelli, Y Honjo, K Ozaki, H Nishino, Y Joti, T Hatsui, F Orsini, R H Menk

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

V Di TrapaniDepartment of Physics, University of Trieste, Via A. Valerio 2, Trieste, 34127, Italy. vittorio.ditrapani@units.it.
P ThibaultDepartment of Physics, University of Trieste, Via A. Valerio 2, Trieste, 34127, Italy.
F ArfelliDepartment of Physics, University of Trieste, Via A. Valerio 2, Trieste, 34127, Italy.
Y HonjoRIKEN SPring-8 Center, RIKEN, 1-1-1, Koto, Sayo-cho, Sayo-gun, Hyogo, 679-5148, Japan.
K OzakiRIKEN SPring-8 Center, RIKEN, 1-1-1, Koto, Sayo-cho, Sayo-gun, Hyogo, 679-5148, Japan.
H NishinoRIKEN SPring-8 Center, RIKEN, 1-1-1, Koto, Sayo-cho, Sayo-gun, Hyogo, 679-5148, Japan.
Y JotiRIKEN SPring-8 Center, RIKEN, 1-1-1, Koto, Sayo-cho, Sayo-gun, Hyogo, 679-5148, Japan.
T HatsuiRIKEN SPring-8 Center, RIKEN, 1-1-1, Koto, Sayo-cho, Sayo-gun, Hyogo, 679-5148, Japan.
F OrsiniRIKEN SPring-8 Center, RIKEN, 1-1-1, Koto, Sayo-cho, Sayo-gun, Hyogo, 679-5148, Japan.
R H MenkElettra-Sincrotrone Trieste, Strada Statale 14 - km 163.5, Basovizza, 34149, Italy.

Funding

European Research Council 866026
6 · The paper itself

Abstract

X-ray spectral imaging is an advanced technique that enables material-sensitive imaging by exploiting energy-dependent interactions with matter. In this context, X-ray fluorescence (XRF) represents the benchmark technique. Despite its excellent elemental sensitivity, however, XRF is intrinsically inefficient because it relies on the detection of isotropically emitted secondary fluorescence induced by a focused beam on the sample. This requirement makes the technique difficult to implement with compact laboratory sources and, especially for tomographic applications, highly brilliant synchrotron sources are required. In a laboratory environment, spectral imaging and tomography are typically performed using photon-counting detectors. While this technology offers significant advantages, the limited number of energy thresholds and coarse energy resolution can hamper the separation of materials with similar attenuation properties. Hyperspectral detectors, featuring sub-keV energy resolution and virtually unlimited spectral binning, provide a technological solution to enable high-sensitivity, chemical-specific imaging in the laboratory. Here we present the first application of the novel CITIUS hyperspectral detector to X-ray micro-CT and radiography at the OptImaTo (Optimal Imaging and Tomography) laboratory (Trieste, Italy), based on a liquid MetalJet source (Excillum, Sweden) with a galinstan anode. Using multiple characteristic emission lines (Ga, In, Sn) and a

Indexed as

Basis material decompositionHyperspectral detectorPhoton-counting CTSpectral imaging

Identifiers

PMID42020683
PMCPMC13273171

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.