Evidence map›Paper›PMID 42020624›Full record

ArticleEuropean radiology2026

Externally validated yet undertrained: sample size deficits in machine learning-based radiomics.

Burak Kocak, Tuba Banaz, Merve Soyleyici, Fadime Kose, Ali Keles, Ismail Mese

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Burak KocakDepartment of Radiology, Basaksehir Cam and Sakura City Hospital, Istanbul, Türkiye. drburakkocak@gmail.com.ORCID http://orcid.org/0000-0002-7307-396X
Tuba BanazDepartment of Radiology, Basaksehir Cam and Sakura City Hospital, Istanbul, Türkiye.ORCID http://orcid.org/0000-0002-7895-4942
Merve SoyleyiciDepartment of Radiology, Basaksehir Cam and Sakura City Hospital, Istanbul, Türkiye.ORCID http://orcid.org/0009-0008-4804-2927
Fadime KoseDepartment of Radiology, Basaksehir Cam and Sakura City Hospital, Istanbul, Türkiye.ORCID http://orcid.org/0000-0003-2445-4974
Ali KelesDepartment of Radiology, Basaksehir Cam and Sakura City Hospital, Istanbul, Türkiye.ORCID http://orcid.org/0000-0003-2474-9983
Ismail MeseDepartment of Radiology, Uskudar State Hospital, Istanbul, Türkiye.ORCID http://orcid.org/0000-0002-4429-6996

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo systematically evaluate training sample size adequacy in externally validated machine learning (ML)-based radiomics models published in high-impact journals and quantify the gap between current practice and theoretical minimum requirements. MATERIALS AND

methodsThis study followed a prespecified and publicly archived protocol. Original research articles published between January 2023 and August 2025 in first quartile (Q1) journals were evaluated. Study selection followed a randomized dynamic screening protocol with a priori power-calculated stopping rule to determine the final cohort. Included studies developed binary prediction models using ML algorithms other than logistic regression and reported external validation. A sample size framework, originally developed for logistic regression, was applied as a conservative lower-bound benchmark. Minimum required sample sizes were calculated based on reported training performance, outcome prevalence, and feature dimensionality.

resultsOf 64 full-text records assessed, 16 (25%) were unassessable due to missing essential parameters (e.g., feature counts) required for sample size estimation. In the assessable final cohort (n = 28), the training sample sizes observed were consistently inadequate, with a median deficit of 195.5 training instances. Only three studies (10.7%) met all criteria for stable prediction model development even under these charitable assumptions. Most studies failed basic heuristics (e.g., 10 events per predictor), with a median events per predictor deficit of 5.8.

conclusionThe vast majority of externally validated radiomics models in high-impact journals are trained on datasets statistically insufficient to support their algorithmic complexity. This systemic data deficit renders models prone to overfitting and instability, potentially explaining the field's reproducibility crisis. KEY POINTS: Question Do externally validated machine learning-based radiomics models in high-impact (Q1) journals have sufficient training sample sizes to support their reported model complexity? Findings Nearly 90% of externally validated radiomics models were trained on statistically insufficient datasets, with a median deficit of approximately 200 training instances. Clinical relevance Insufficient training sample sizes undermine model stability and contribute to the reproducibility crisis in radiomics, allowing externally validated models to appear robust while generating unreliable predictions that may misinform clinical decision-making.

Indexed as

Machine LearningRadiomicsAlgorithmsHumansReproducibility of ResultsSample SizeArtificial intelligenceMachine learningRadiomicsReproducibility of resultsSample size

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.