Evidence map›Paper›PMID 42019156›Full record

ArticleInjury2026

Finite element modeling of lag screw with plate fracture fixation: Effects of screw angle, countersinking, and plate configuration.

Hwabok Wee, J Spence Reid, Gregory S Lewis

Abstract read
In one paragraph

Article in Injury, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Hwabok WeeDepartment of Orthopaedics and Therapy Services, Penn State College of Medicine, Hershey, PA 17033, USA.
J Spence ReidDepartment of Orthopaedics and Therapy Services, Penn State College of Medicine, Hershey, PA 17033, USA.
Gregory S LewisDepartment of Orthopaedics and Therapy Services, Penn State College of Medicine, Hershey, PA 17033, USA. Electronic address: greglewis@psu.edu.

Funding

Fracture Fixation Biomechanics Simulator with Adaptive Virtual CoachingR01EB029207 · NIBIB · PENNSYLVANIA STATE UNIV HERSHEY MED CTR · PI LEWIS, GREGORY STEPHEN, REID , JOHN SPENCE · 2020 to 2023
$1.2M
NIBIB NIH HHS R01 EB029207
6 · The paper itself

Abstract

introductionA lag screw, or a lag screw combined with a neutralization plate, is commonly used for compressive fixation of simple fracture patterns. There are several surgical variables that potentially affect fixation stability including lag screw angle, fracture gap, screw countersinking, screw diameter, and neutralization plate configuration.

methodsThis study involved finite element modeling of these biomechanics in a diaphyseal bicortical oblique fracture model of (1) lag screw application under controlled torque; and (2) postoperative stability with 4.5 mm diameter lag screw and corresponding neutralization plate combinations, subject to external compression, bending, and torsion.

resultsIn models of lag screw application, predicted interfragmentary misalignment had good agreement with corresponding validation experiments. When the screw was applied perpendicular to the fracture, with moderate countersinking and no initial fracture gap, fracture compression was maximized and interfragmentary misalignment minimized. A 30° deviation from perpendicular screw placement reduced fracture compression by 19% and produced 0.7 mm of interfragmentary misalignment, while screw deviation at 15° had negligible effects. Not countersinking the screw head also decreased fracture compression and increased lag screw stress at the head-shaft junction, with the model predicting larger effects on compression than observed in the experiment. During postoperative loading, the addition of a neutralization plate limited shear interfragmentary motion to < 0.4 mm under all loadings, and reduced lag screw stress and bone strains, particularly under torsion.

conclusionThe study quantifies the decreases in fracture compression in lag screw fixation due to screw angular deviation and not countersinking the screw head, and characterizes the biomechanical benefits of combining lag screw fixation with a neutralization plate.

Indexed as

Bone PlatesBone ScrewsFemoral FracturesFinite Element AnalysisFracture Fixation, InternalBiomechanical PhenomenaHumansStress, MechanicalTorqueBiomechanicsFinite element analysisFracture compressionFracture fixationLag screwNeutralization plateOblique fracture

Identifiers

PMID42019156
PMCPMC13292831

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.