Evidence map›Paper›PMID 42017042›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2026

Joint Cone-Beam CT Reconstruction and Rigid Motion Compensation Using A Differentiable Projector.

Xin Wang, Xiao Jiang, Yue Fan, Wojciech Zbijewski, J Webster Stayman

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xin WangDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD, 21205, USA.
Xiao JiangDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD, 21205, USA.
Yue FanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD, 21205, USA.
Wojciech ZbijewskiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD, 21205, USA.
J Webster StaymanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore MD, 21205, USA.

Funding

Deformable motion compensation for 3D image-guided interventional radiologyR01EB030547 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI ZBIJEWSKI, WOJCIECH BARTOSZ · 2021 to 2024
$1.5M
NIBIB NIH HHS R01 EB030547
6 · The paper itself

Abstract

Purpose: To develop and assess the feasibility of integrating model-based CBCT reconstruction with rigid motion estimation, using only a projection-domain data fidelity objective coupled with a differentiable forward projector. Methods: We propose a joint image reconstruction and motion estimation framework that integrates motion compensation directly into a model-based iterative reconstruction (MBIR) scheme. Rigid motion with six degrees of freedom (DoF) is modeled as geometric perturbations that alter the projection geometry and thereby affect the estimated projections. To enable gradient-based optimization, a differentiable forward projector with an analytical gradient formulation is employed, allowing efficient backpropagation of the loss between the estimated and measured projections. Within this differentiable framework, the motion parameters and attenuation volume are optimized simultaneously. To evaluate the proposed method, we conducted both simulation and physical phantom studies. In the simulation study, we assessed performance under jerk motion with progressively increasing motion amplitudes, ranging from 1 mm to 10 mm in translation and from 0.02 rad to 0.2 rad in rotation. Reconstruction accuracy was quantified using structural similarity index (SSIM) relative to motion-free ground truth. In the physical phantom study, a jerk motion of 5 mm translation and 0.1 rad rotation was applied during scanning. Motion-free, motion-corrupted, and motion-compensated reconstructions were displayed side-by-side for qualitative comparison, enabling visual assessment of motion artifact reduction. Results: The experimental results demonstrate that the proposed motion compensation method substantially enhances image quality across a range of motion amplitudes. Qualitative evaluation reveal that even under significant translational and rotational motion, the method effectively recovers anatomical structures with minimal residual errors. In simulation studies, SSIM values improved by 18%, 37%, and 48% for motion amplitudes (3 mm, 0.06 rad), (6 mm, 0.12 rad), and (9 mm, 0.18 rad), respectively. Reconstructions from physical bench data further confirm efficacy, showing restored sharpness and anatomical continuity across coronal and sagittal planes. Conclusion: The discrepancy between the estimated and acquired projections serves as a sufficient objective for jointly estimating both the image volume and motion parameters, potentially avoiding the need for image-based sharpness criteria.

Identifiers

PMID42017042
PMCPMC13095155

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.