ArticleProceedings of SPIE--the International Society for Optical Engineering2026
System design options for a high-resolution, conventional scintillator detector.
Article in Proceedings of SPIE--the International Society for Optical Engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
Abstract
It is commonly believed that energy integrating detector (EID) CT has limited spatial resolution because of reflective septa placed around each pixel. Reducing the pixel size would increase the proportion of detector area lost. We point out that this can be avoided if the detector is tilted, because then rays would penetrate reflective septa and reach buried scintillator. But how should this be accomplished? We consider three options for system design: (1) with the false focal spot geometry, the detector is focused at a "false" point about 5 cm from the true focal spot. The anti-scatter grid (ASG) must still point towards the true focal spot. (2) With tilted detector modules, each detector tile is tilted by a few degrees. Slight discontinuities are created at boundaries between tiles, which could cause artifacts if not appropriately handled. The anti-scatter grid would have to float above some pixels. (3) With tilted cuts, the scintillator is structured with angled cuts rather than vertical cuts before the cuts are infilled with reflective septa. This minimizes changes to reconstruction and the ASG. All three options would improve fill factor. Using ray tracing simulations and assuming a reflective septa width of 0.1 mm, we estimate that the effective fill factor is increased from 81% for a conventional, 1 mm pitch detector to 91% with a high-resolution, 0.5 mm pitch detector that is tilted. These concepts open up a pathway for high-resolution CT without requiring photon counting technology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.